CVE-2025-27253
Last modified
CVE-2025-27253 is a medium-severity vulnerability rated 6.1/10 on the CVSS scale. A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network.. EPSS estimates a 0.22% chance of exploitation in the next 30 days.
Description
A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network.
Metrics
Weakness Enumeration
References
Timeline
- Published
- Last Modified
- Status
- Deferred
Frequently Asked Questions
What is CVE-2025-27253?
How severe is CVE-2025-27253?
How do I fix CVE-2025-27253?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2025
- CVE-2025-27247in OpenHarmony v5.0.3 and prior versions allow a local attac…5.5
- CVE-2025-27248in OpenHarmony v5.0.3 and prior versions allow a local attac…5.5
- CVE-2025-27249Uncontrolled resource consumption for some Gaudi software be…6.8
- CVE-2025-2725A vulnerability classified as critical was found in H3C Magi…8.6
- CVE-2025-27250Uncontrolled resource consumption for some Edge Orchestrator…5.1
- CVE-2025-27251Rejected reason: This CVE ID has been rejected or withdrawn …
- CVE-2025-27254CWE-282 "Improper Ownership Management" in GE Vernova EnerVi…8
- CVE-2025-27255Use of Hard-coded Credentials vulnerability in GE Vernova En…8
- CVE-2025-27256Missing Authentication for Critical Function vulnerability i…8.3
- CVE-2025-27257Insufficient Verification of Data Authenticity vulnerability…6.1
- CVE-2025-27258Ericsson Network Manager (ENM) versions prior to ENM 25.1 GA…9.8
- CVE-2025-27259Ericsson Network Manager versions prior to ENM 25.2 GA conta…5.4
Are you affected by CVE-2025-27253?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST