CVE-2025-3947

HIGHCVSS 8.2/10EPSS 0.32%

Last modified

CVE-2025-3947 is a high-severity vulnerability rated 8.2/10 on the CVSS scale. The Honeywell Experion PKS contains an Integer Underflow vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to Input Data Manipulation, which could result in improper integer data value checking during subtraction leading to a denial of service. Honeywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. EPSS estimates a 0.32% chance of exploitation in the next 30 days.

Description

The Honeywell Experion PKS contains an Integer Underflow vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to Input Data Manipulation, which could result in improper integer data value checking during subtraction leading to a denial of service. Honeywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.

Metrics

CVSS 3.1
8.2/10

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H

EPSS Probability
0.32%

23.2th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

References

Timeline

Published
Last Modified
Status
Deferred

Frequently Asked Questions

What is CVE-2025-3947?
The Honeywell Experion PKS contains an Integer Underflow vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to Input Data Manipulation, which could result in improper integer data value checking during subtraction leading to a denial of service. Honeywell recommends updating to the most recent version of Honeywell Experion PKS:520.2 TCU9 HF1 and 530.1 TCU3 HF1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.
How severe is CVE-2025-3947?
CVE-2025-3947 has a CVSS score of 8.2/10 (HIGH severity). The EPSS model estimates a 0.32% probability of exploitation in the next 30 days.
How do I fix CVE-2025-3947?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2025-3947?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST