CVE-2025-41109

HIGHCVSS 8.7/10EPSS 0.60%

Last modified

CVE-2025-41109 is a high-severity vulnerability rated 8.7/10 on the CVSS scale. Ghost Robotics Vision 60 v0.27.2 includes, among its physical interfaces, three RJ45 connectors and a USB Type-C port. The vulnerability is due to the lack of authentication mechanisms when establishing connections through these ports. EPSS estimates a 0.60% chance of exploitation in the next 30 days.

Description

Ghost Robotics Vision 60 v0.27.2 includes, among its physical interfaces, three RJ45 connectors and a USB Type-C port. The vulnerability is due to the lack of authentication mechanisms when establishing connections through these ports. Specifically, with regard to network connectivity, the robot's internal router automatically assigns IP addresses to any device physically connected to it. An attacker could connect a WiFi access point under their control to gain access to the robot's network without needing the credentials for the deployed network. Once inside, the attacker can monitor all its data, as the robot runs on ROS 2 without authentication by default.

Metrics

CVSS 3.1
4.6/10

CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

CVSS 4.0
8.7/10

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

EPSS Probability
0.60%

44.2th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
GhostroboticsVision 60 Firmware0.27.2

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2025-41109?
Ghost Robotics Vision 60 v0.27.2 includes, among its physical interfaces, three RJ45 connectors and a USB Type-C port. The vulnerability is due to the lack of authentication mechanisms when establishing connections through these ports. Specifically, with regard to network connectivity, the robot's internal router automatically assigns IP addresses to any device physically connected to it. An attacker could connect a WiFi access point under their control to gain access to the robot's network without needing the credentials for the deployed network. Once inside, the attacker can monitor all its data, as the robot runs on ROS 2 without authentication by default.
How severe is CVE-2025-41109?
CVE-2025-41109 has a CVSS score of 8.7/10 (HIGH severity). The EPSS model estimates a 0.60% probability of exploitation in the next 30 days.
How do I fix CVE-2025-41109?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2025-41109?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST