CVE-2025-41693

MEDIUMCVSS 4.3/10EPSS 0.43%

Last modified

CVE-2025-41693 is a medium-severity vulnerability rated 4.3/10 on the CVSS scale. A low privileged remote attacker can use the ssh feature to execute commands directly after login. The process stays open and uses resources which leads to a reduced performance of the management functions. EPSS estimates a 0.43% chance of exploitation in the next 30 days.

Description

A low privileged remote attacker can use the ssh feature to execute commands directly after login. The process stays open and uses resources which leads to a reduced performance of the management functions. Switching functionality is not affected.

Metrics

CVSS 3.1
4.3/10

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L

EPSS Probability
0.43%

34.6th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
PhoenixcontactFl Switch 2708 Pn Firmware< 3.50
PhoenixcontactFl Switch 2708 Firmware< 3.50
PhoenixcontactFl Switch 2608 Pn Firmware< 3.50
PhoenixcontactFl Switch 2608 Firmware< 3.50
PhoenixcontactFl Switch 2516 Pn Firmware< 3.50
PhoenixcontactFl Switch 2516 Firmware< 3.50
PhoenixcontactFl Switch 2514-2sfp Pn Firmware< 3.50
PhoenixcontactFl Switch 2514-2sfp Firmware< 3.50
PhoenixcontactFl Switch 2512-2gc-2sfp Firmware< 3.50
PhoenixcontactFl Switch 2508 Pn Firmware< 3.50
PhoenixcontactFl Switch 2508\/K1 Firmware< 3.50
PhoenixcontactFl Switch 2508 Firmware< 3.50
PhoenixcontactFl Switch 2506-2sfp Pn Firmware< 3.50
PhoenixcontactFl Switch 2506-2sfp\/K1 Firmware< 3.50
PhoenixcontactFl Switch 2506-2sfp Firmware< 3.50
PhoenixcontactFl Switch 2504-2gc-2sfp Firmware< 3.50
PhoenixcontactFl Switch 2416 Pn Firmware< 3.50
PhoenixcontactFl Switch 2416 Firmware< 3.50
PhoenixcontactFl Switch 2414-2sfx Pn Firmware< 3.50
PhoenixcontactFl Switch 2414-2sfx Firmware< 3.50
PhoenixcontactFl Switch 2412-2tc-2sfx Firmware< 3.50
PhoenixcontactFl Switch 2408 Pn Firmware< 3.50
PhoenixcontactFl Switch 2408 Firmware< 3.50
PhoenixcontactFl Switch 2406-2sfx Pn Firmware< 3.50
PhoenixcontactFl Switch 2406-2sfx Firmware< 3.50
PhoenixcontactFl Switch 2404-2tc-2sfx Firmware< 3.50
PhoenixcontactFl Switch 2316 Pn Firmware< 3.50
PhoenixcontactFl Switch 2316\/K1 Firmware< 3.50
PhoenixcontactFl Switch 2316 Firmware< 3.50
PhoenixcontactFl Switch 2314-2sfp Pn Firmware< 3.50
PhoenixcontactFl Switch 2314-2sfp Firmware< 3.50
PhoenixcontactFl Switch 2312-2gc-2sfp Firmware< 3.50
PhoenixcontactFl Switch 2308 Pn Firmware< 3.50
PhoenixcontactFl Switch 2308 Firmware< 3.50
PhoenixcontactFl Switch 2306-2sfp Pn Firmware< 3.50
PhoenixcontactFl Switch 2306-2sfp Firmware< 3.50
PhoenixcontactFl Switch 2304-2gc-2sfp Firmware< 3.50
PhoenixcontactFl Switch 2303-8sp1< 3.50
PhoenixcontactFl Switch 2216 Pn Firmware< 3.50
PhoenixcontactFl Switch 2216 Firmware< 3.50
PhoenixcontactFl Switch 2214-2sfx Pn Firmware< 3.50
PhoenixcontactFl Switch 2214-2sfx Firmware< 3.50
PhoenixcontactFl Switch 2214-2fx Sm Firmware< 3.50
PhoenixcontactFl Switch 2214-2fx Firmware< 3.50
PhoenixcontactFl Switch 2212-2tc-2sfx Firmware< 3.50
PhoenixcontactFl Switch 2208c Firmware< 3.50
PhoenixcontactFl Switch 2208 Pn Firmware< 3.50
PhoenixcontactFl Switch 2208 Firmware< 3.50
PhoenixcontactFl Switch 2207-Fx Sm Firmware< 3.50
PhoenixcontactFl Switch 2207-Fx Firmware< 3.50

Showing 50 of 69 affected configurations. See NVD for the full list.

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2025-41693?
A low privileged remote attacker can use the ssh feature to execute commands directly after login. The process stays open and uses resources which leads to a reduced performance of the management functions. Switching functionality is not affected.
How severe is CVE-2025-41693?
CVE-2025-41693 has a CVSS score of 4.3/10 (MEDIUM severity). The EPSS model estimates a 0.43% probability of exploitation in the next 30 days.
How do I fix CVE-2025-41693?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2025-41693?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST