CVE-2025-52586

HIGHCVSS 7.5/10EPSS 0.07%

Last modified

CVE-2025-52586 is a high-severity vulnerability rated 7.5/10 on the CVSS scale. The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.. EPSS estimates a 0.07% chance of exploitation in the next 30 days.

Description

The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.

Metrics

CVSS 3.1
6.9/10

CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L

CVSS 4.0
7.5/10

CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

EPSS Probability
0.07%

0.1th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

References

Timeline

Published
Last Modified
Status
Deferred

Frequently Asked Questions

What is CVE-2025-52586?
The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.
How severe is CVE-2025-52586?
CVE-2025-52586 has a CVSS score of 7.5/10 (HIGH severity). The EPSS model estimates a 0.07% probability of exploitation in the next 30 days.
How do I fix CVE-2025-52586?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2025-52586?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST