CVE-2025-5946

HIGHCVSS 7.2/10EPSS 13.84%

Last modified

CVE-2025-5946 is a high-severity vulnerability rated 7.2/10 on the CVSS scale. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.. EPSS estimates a 13.84% chance of exploitation in the next 30 days.

Description

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.

Metrics

CVSS 3.1
7.2/10

CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

EPSS Probability
13.84%

96.0th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
CentreonCentreon Web>= 23.10.0, < 23.10.28
CentreonCentreon Web>= 24.04.0, < 24.04.18
CentreonCentreon Web>= 24.10.0, < 24.10.13

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2025-5946?
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
How severe is CVE-2025-5946?
CVE-2025-5946 has a CVSS score of 7.2/10 (HIGH severity). The EPSS model estimates a 13.84% probability of exploitation in the next 30 days.
How do I fix CVE-2025-5946?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2025-5946?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST