CVE-2025-7850
CRITICALCVSS 9.3/10EPSS 2.17%
Last modified
CVE-2025-7850 is a critical-severity vulnerability rated 9.3/10 on the CVSS scale. A command injection vulnerability may be exploited after the admin's authentication on the web portal on Omada gateways.. EPSS estimates a 2.17% chance of exploitation in the next 30 days.
Description
A command injection vulnerability may be exploited after the admin's authentication on the web portal on Omada gateways.
Metrics
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Tp-Link | Er8411 Firmware | < 1.3.3 |
| Tp-Link | Er8411 Firmware | 1.3.3 |
| Tp-Link | Er7412-M2 Firmware | < 1.1.0 |
| Tp-Link | Er7412-M2 Firmware | 1.1.0 |
| Tp-Link | Er707-M2 Firmware | < 1.3.1 |
| Tp-Link | Er707-M2 Firmware | 1.3.1 |
| Tp-Link | Er7206 Firmware | < 2.2.2 |
| Tp-Link | Er7206 Firmware | 2.2.2 |
| Tp-Link | Er605 Firmware | < 2.3.1 |
| Tp-Link | Er605 Firmware | 2.3.1 |
| Tp-Link | Er706w Firmware | < 1.2.1 |
| Tp-Link | Er706w Firmware | 1.2.1 |
| Tp-Link | Er706w-4g Firmware | < 1.2.1 |
| Tp-Link | Er706w-4g Firmware | 1.2.1 |
| Tp-Link | Er7212pc Firmware | < 2.1.3 |
| Tp-Link | Er7212pc Firmware | 2.1.3 |
| Tp-Link | G36 Firmware | < 1.1.4 |
| Tp-Link | G36 Firmware | 1.1.4 |
| Tp-Link | G611 Firmware | < 1.2.2 |
| Tp-Link | G611 Firmware | 1.2.2 |
| Tp-Link | Fr365 Firmware | < 1.1.10 |
| Tp-Link | Fr365 Firmware | 1.1.10 |
| Tp-Link | Fr205 Firmware | < 1.0.3 |
| Tp-Link | Fr205 Firmware | 1.0.3 |
| Tp-Link | Fr307-M2 Firmware | < 1.2.5 |
| Tp-Link | Fr307-M2 Firmware | 1.2.5 |
References
- https://support.omadanetworks.com/en/document/108456/Vendor Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2025-7850?
A command injection vulnerability may be exploited after the admin's authentication on the web portal on Omada gateways.
How severe is CVE-2025-7850?
CVE-2025-7850 has a CVSS score of 9.3/10 (CRITICAL severity). The EPSS model estimates a 2.17% probability of exploitation in the next 30 days.
How do I fix CVE-2025-7850?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.
Are you affected by CVE-2025-7850?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST