CVE-2026-120295

HIGHCVSS 7.1/10EPSS 0.24%

Last modified

CVE-2026-120295 is a high-severity vulnerability rated 7.1/10 on the CVSS scale. Incorrect Authorization vulnerability in the devices page bulk move in nerves-hub nerves_hub_web allows an authenticated user with the manage role in one organization and only the view role in another to move devices into the second organization's product via the "Move device(s) to product" action. The target-product event in NervesHubWeb.Live.Devices.Index looks the product up with NervesHub.Products.get_by_id/2, which checks that the user is a member of the product's organization at any role, and move-devices-product then changes each selected device's organization and product. EPSS estimates a 0.24% chance of exploitation in the next 30 days.

Description

Incorrect Authorization vulnerability in the devices page bulk move in nerves-hub nerves_hub_web allows an authenticated user with the manage role in one organization and only the view role in another to move devices into the second organization's product via the "Move device(s) to product" action. The target-product event in NervesHubWeb.Live.Devices.Index looks the product up with NervesHub.Products.get_by_id/2, which checks that the user is a member of the product's organization at any role, and move-devices-product then changes each selected device's organization and product. The device API's move requires manage in the target organization, and an earlier fix added the check on the organization the devices leave but not on the one they enter. A moved device keeps its key and certificate, joins the target organization's matching deployment groups, and is sent their firmware with a download URL, which the view role cannot otherwise obtain. The user cannot change or control devices that already belong to the other organization. This issue affects nerves_hub: from 1.0.0 before 2.5.3.

Metrics

Weakness Enumeration

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
nerves-hubnerves_hub_web>= 1.0.0, < 2.5.3
nerves-hubnerves_hub_web>= adaeefdb7a835525482588f43332ef988cc448c7, < *; >= 79743ef08f7f801617b653fd09f37c01ed9b4be0, < 1bc8be875ab6b1eb904e5ff60c8a1421c5c700fa

References

Timeline

Published
Last Modified
Status
Deferred

Frequently Asked Questions

What is CVE-2026-120295?
Incorrect Authorization vulnerability in the devices page bulk move in nerves-hub nerves_hub_web allows an authenticated user with the manage role in one organization and only the view role in another to move devices into the second organization's product via the "Move device(s) to product" action. The target-product event in NervesHubWeb.Live.Devices.Index looks the product up with NervesHub.Products.get_by_id/2, which checks that the user is a member of the product's organization at any role, and move-devices-product then changes each selected device's organization and product. The device API's move requires manage in the target organization, and an earlier fix added the check on the organization the devices leave but not on the one they enter. A moved device keeps its key and certificate, joins the target organization's matching deployment groups, and is sent their firmware with a download URL, which the view role cannot otherwise obtain. The user cannot change or control devices that already belong to the other organization. This issue affects nerves_hub: from 1.0.0 before 2.5.3.
How severe is CVE-2026-120295?
CVE-2026-120295 has a CVSS score of 7.1/10 (HIGH severity). The EPSS model estimates a 0.24% probability of exploitation in the next 30 days.
How do I fix CVE-2026-120295?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-120295?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST