CVE-2026-120730

HIGHCVSS 8.6/10EPSS 0.36%

Last modified

CVE-2026-120730 is a high-severity vulnerability rated 8.6/10 on the CVSS scale. Improperly Controlled Modification of Dynamically-Determined Object Attributes vulnerability in the device API, device forms, signing key and product forms and JITP settings in nerves-hub nerves_hub_web allows an authenticated user who manages devices in any organization to write into other organizations via submitted org_id, product_id and deployment_id fields. The device API create and update actions and the dashboard device forms pass the request parameters to NervesHub.Devices.Device.changeset/2, which casts the organization, product, deployment group and update state as given. EPSS estimates a 0.36% chance of exploitation in the next 30 days.

Description

Improperly Controlled Modification of Dynamically-Determined Object Attributes vulnerability in the device API, device forms, signing key and product forms and JITP settings in nerves-hub nerves_hub_web allows an authenticated user who manages devices in any organization to write into other organizations via submitted org_id, product_id and deployment_id fields. The device API create and update actions and the dashboard device forms pass the request parameters to NervesHub.Devices.Device.changeset/2, which casts the organization, product, deployment group and update state as given. The signing key and product forms merge the session's organization into the submitted parameters so that a submitted org_id wins, and the JITP changeset accepts any product_id. Each request requires the manage role only in the user's own organization, and any account can create one. A device placed on another organization's deployment group, or moved into its product, is sent that organization's firmware with a download URL. The user cannot change or control devices that already belong to the other organization, and cannot upload firmware to it. This issue affects nerves_hub: from 1.0.0 before 2.5.3.

Metrics

Weakness Enumeration

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
nerves-hubnerves_hub_web>= 1.0.0, < 2.5.3
nerves-hubnerves_hub_web>= f58d58233dbd355c58d3a140107ece18e8863f14, < c367d7d17d07f843e78a70d15904665616dde964

References

Timeline

Published
Last Modified
Status
Deferred

Frequently Asked Questions

What is CVE-2026-120730?
Improperly Controlled Modification of Dynamically-Determined Object Attributes vulnerability in the device API, device forms, signing key and product forms and JITP settings in nerves-hub nerves_hub_web allows an authenticated user who manages devices in any organization to write into other organizations via submitted org_id, product_id and deployment_id fields. The device API create and update actions and the dashboard device forms pass the request parameters to NervesHub.Devices.Device.changeset/2, which casts the organization, product, deployment group and update state as given. The signing key and product forms merge the session's organization into the submitted parameters so that a submitted org_id wins, and the JITP changeset accepts any product_id. Each request requires the manage role only in the user's own organization, and any account can create one. A device placed on another organization's deployment group, or moved into its product, is sent that organization's firmware with a download URL. The user cannot change or control devices that already belong to the other organization, and cannot upload firmware to it. This issue affects nerves_hub: from 1.0.0 before 2.5.3.
How severe is CVE-2026-120730?
CVE-2026-120730 has a CVSS score of 8.6/10 (HIGH severity). The EPSS model estimates a 0.36% probability of exploitation in the next 30 days.
How do I fix CVE-2026-120730?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-120730?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST