CVE-2026-133851

MEDIUMCVSS 5.3/10

Last modified

CVE-2026-133851 is a medium-severity vulnerability rated 5.3/10 on the CVSS scale. FlowIntel's alerting module contained an authorization bypass in the alert access control logic. When an alert was linked to a private case, the system relied solely on connector ownership (user or organization) to determine access, without verifying that the requesting user still held valid membership in the associated private case. This meant that a user who was a connector owner of an alert could continue to read alert details, review history, raw payloads, and action comments, and could perform review-status updates or case-creation actions, even after their access to the linked private case had been revoked or they were never a member of that case. Additionally, a time-of-check to time-of-use (TOCTOU) gap existed: after a review-status update or a competing case-creation claim was committed, the response could disclose private case identifiers or review history to a user whose access had been concurrently removed by another session linking the alert to a private case. Impact: - Unauthorized disclosure of private case data (review comments, raw payloads, action history) through alert endpoints. - Unauthorized modification of alert review status and creation of cases from alerts the user should no longer access. - Leakage of a competing case identifier to an unauthorized user during concurrent case-creation races. Affected versions: FlowIntel prior to 4.1.0..

Description

FlowIntel's alerting module contained an authorization bypass in the alert access control logic. When an alert was linked to a private case, the system relied solely on connector ownership (user or organization) to determine access, without verifying that the requesting user still held valid membership in the associated private case. This meant that a user who was a connector owner of an alert could continue to read alert details, review history, raw payloads, and action comments, and could perform review-status updates or case-creation actions, even after their access to the linked private case had been revoked or they were never a member of that case. Additionally, a time-of-check to time-of-use (TOCTOU) gap existed: after a review-status update or a competing case-creation claim was committed, the response could disclose private case identifiers or review history to a user whose access had been concurrently removed by another session linking the alert to a private case. Impact: - Unauthorized disclosure of private case data (review comments, raw payloads, action history) through alert endpoints. - Unauthorized modification of alert review status and creation of cases from alerts the user should no longer access. - Leakage of a competing case identifier to an unauthorized user during concurrent case-creation races. Affected versions: FlowIntel prior to 4.1.0.

Metrics

Weakness Enumeration

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
flowintelflowintel< 4.1.0

References

Timeline

Published
Last Modified
Status
Received

Frequently Asked Questions

What is CVE-2026-133851?
FlowIntel's alerting module contained an authorization bypass in the alert access control logic. When an alert was linked to a private case, the system relied solely on connector ownership (user or organization) to determine access, without verifying that the requesting user still held valid membership in the associated private case. This meant that a user who was a connector owner of an alert could continue to read alert details, review history, raw payloads, and action comments, and could perform review-status updates or case-creation actions, even after their access to the linked private case had been revoked or they were never a member of that case. Additionally, a time-of-check to time-of-use (TOCTOU) gap existed: after a review-status update or a competing case-creation claim was committed, the response could disclose private case identifiers or review history to a user whose access had been concurrently removed by another session linking the alert to a private case. Impact: - Unauthorized disclosure of private case data (review comments, raw payloads, action history) through alert endpoints. - Unauthorized modification of alert review status and creation of cases from alerts the user should no longer access. - Leakage of a competing case identifier to an unauthorized user during concurrent case-creation races. Affected versions: FlowIntel prior to 4.1.0.
How severe is CVE-2026-133851?
CVE-2026-133851 has a CVSS score of 5.3/10 (MEDIUM severity).
How do I fix CVE-2026-133851?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-133851?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST