CVE-2026-16933

HIGHCVSS 8.2/10EPSS 0.12%

Last modified

CVE-2026-16933 is a high-severity vulnerability rated 8.2/10 on the CVSS scale. IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.. EPSS estimates a 0.12% chance of exploitation in the next 30 days.

Description

IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.

Metrics

EPSS Probability
0.12%

2.3th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
IbmPower System S1122 \(9824-22a\) Firmware>= fw1110.00, < fw1110.31
IbmPower System S1122 \(9824-22a\) Firmwarefw1120.00
IbmPower System S1124 \(9824-42a\) Firmware>= fw1110.00, < fw1110.31
IbmPower System S1124 \(9824-42a\) Firmwarefw1120.00
IbmPower System S1122s \(9824-22b\) Firmware>= fw1110.00, < fw1110.31
IbmPower System S1122s \(9824-22b\) Firmwarefw1120.00
IbmPower System S1114 \(9824-41b\) Firmware>= fw1110.00, < fw1110.31
IbmPower System S1114 \(9824-41b\) Firmwarefw1120.00
IbmPower System L1122 \(9856-22h\) Firmware>= fw1110.00, < fw1110.31
IbmPower System L1122 \(9856-22h\) Firmwarefw1120.00
IbmPower System L1124 \(9856-42h\) Firmware>= fw1110.00, < fw1110.31
IbmPower System L1124 \(9856-42h\) Firmwarefw1120.00
IbmPower System E1150 \(9043-Mru\) Firmware>= fw1110.00, < fw1110.31
IbmPower System E1150 \(9043-Mru\) Firmwarefw1120.00
IbmPower System S1112 \(9242-21b\) Firmwarefw1120.00
IbmPower System S1112 \(9242-21t\) Firmwarefw1120.00
IbmPower System E1080 \(9080-Hex\) Firmware>= fw1060.00, < fw1060.81
IbmPower System S1022 \(9105-22a\) Firmware>= fw1060.00, < fw1060.81
IbmPower System S1024 \(9105-42a\) Firmware>= fw1060.00, < fw1060.81
IbmPower System S1022s \(9105-22b\) Firmware>= fw1060.00, < fw1060.81
IbmPower System S1014 \(9105-41b\) Firmware>= fw1060.00, < fw1060.81
IbmPower System L1022 \(9786-22h\) Firmware>= fw1060.00, < fw1060.81
IbmPower System L1024 \(9786-42h\) Firmware>= fw1060.00, < fw1060.81
IbmPower System E1050 \(9043-Mrx\) Firmware>= fw1060.00, < fw1060.81
IbmPower System S1012 \(9028-21b\) Firmware>= fw1060.00, < fw1060.81
IbmPower System E1180 \(9080-Heu\) Firmware>= fw1110.00, < fw1110.31
IbmPower System E1180 \(9080-Heu\) Firmwarefw1120.00
IbmPower System S922 \(9009-22g\) Firmware>= fw950.00, < fw950.h3
IbmPower System H922 \(9223-22s\) Firmware>= fw950.00, < fw950.h3
IbmPower System S914 \(9009-41g\) Firmware>= fw950.00, < fw950.h3
IbmPower System S924 \(9009-42g\) Firmware>= fw950.00, < fw950.h3
IbmPower System H924 \(9223-42s\) Firmware>= fw950.00, < fw950.h3
IbmPower System E950 \(9040-Mr9\) Firmware>= fw950.00, < fw950.h3
IbmPower System E980 \(9080-M9s\) Firmware>= fw950.00, < fw950.h3
IbmPower System Ac922 \(8335-Gth\) Firmware>= op940, < op940.a2
IbmPower System Ac922 \(8335-Gtx\) Firmware>= op940, < op940.a2
IbmPower Hardware Management Console \(7063-Cr2\) Firmware>= op940, < op940.82

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2026-16933?
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 through OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can read and write arbitrary regions of host system memory, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.
How severe is CVE-2026-16933?
CVE-2026-16933 has a CVSS score of 8.2/10 (HIGH severity). The EPSS model estimates a 0.12% probability of exploitation in the next 30 days.
How do I fix CVE-2026-16933?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-16933?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST