CVE-2026-17097

MEDIUMCVSS 6.7/10EPSS 0.11%

Last modified

CVE-2026-17097 is a medium-severity vulnerability rated 6.7/10 on the CVSS scale. IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the PowerVM hypervisor call interface. An attacker with root access to a guest partition can issue a specially crafted hypervisor call causing a virtual processor to become permanently unresponsive, requiring a full platform re-IPL to restore normal operation. EPSS estimates a 0.11% chance of exploitation in the next 30 days.

Description

IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the PowerVM hypervisor call interface. An attacker with root access to a guest partition can issue a specially crafted hypervisor call causing a virtual processor to become permanently unresponsive, requiring a full platform re-IPL to restore normal operation. In some cases this may also cause the guest to inject a small amount of data into hypervisor or partition memory with no attacker control over the target location. Successful exploitation results in an integrity and availability impact to the managed system.

Metrics

EPSS Probability
0.11%

1.4th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
IbmPower System S1122 \(9824-22a\) Firmware>= fw1110.00, < fw1110.31
IbmPower System S1122 \(9824-22a\) Firmwarefw1120.00
IbmPower System S1124 \(9824-42a\) Firmware>= fw1110.00, < fw1110.31
IbmPower System S1124 \(9824-42a\) Firmwarefw1120.00
IbmPower System S1122s \(9824-22b\) Firmware>= fw1110.00, < fw1110.31
IbmPower System S1122s \(9824-22b\) Firmwarefw1120.00
IbmPower System S1114 \(9824-41b\) Firmware>= fw1110.00, < fw1110.31
IbmPower System S1114 \(9824-41b\) Firmwarefw1120.00
IbmPower System L1122 \(9856-22h\) Firmware>= fw1110.00, < fw1110.31
IbmPower System L1122 \(9856-22h\) Firmwarefw1120.00
IbmPower System L1124 \(9856-42h\) Firmware>= fw1110.00, < fw1110.31
IbmPower System L1124 \(9856-42h\) Firmwarefw1120.00
IbmPower System E1150 \(9043-Mru\) Firmware>= fw1110.00, < fw1110.31
IbmPower System E1150 \(9043-Mru\) Firmwarefw1120.00
IbmPower System S1112 \(9242-21b\) Firmwarefw1120.00
IbmPower System S1112 \(9242-21t\) Firmwarefw1120.00
IbmPower System E1080 \(9080-Hex\) Firmware>= fw1060.00, < fw1060.81
IbmPower System S1022 \(9105-22a\) Firmware>= fw1060.00, < fw1060.81
IbmPower System S1024 \(9105-42a\) Firmware>= fw1060.00, < fw1060.81
IbmPower System S1022s \(9105-22b\) Firmware>= fw1060.00, < fw1060.81
IbmPower System S1014 \(9105-41b\) Firmware>= fw1060.00, < fw1060.81
IbmPower System L1022 \(9786-22h\) Firmware>= fw1060.00, < fw1060.81
IbmPower System L1024 \(9786-42h\) Firmware>= fw1060.00, < fw1060.81
IbmPower System E1050 \(9043-Mrx\) Firmware>= fw1060.00, < fw1060.81
IbmPower System S1012 \(9028-21b\) Firmware>= fw1060.00, < fw1060.81
IbmPower System E1180 \(9080-Heu\) Firmware>= fw1110.00, < fw1110.31
IbmPower System E1180 \(9080-Heu\) Firmwarefw1120.00
IbmPower System S922 \(9009-22g\) Firmware>= fw950.00, < fw950.h3
IbmPower System H922 \(9223-22s\) Firmware>= fw950.00, < fw950.h3
IbmPower System S914 \(9009-41g\) Firmware>= fw950.00, < fw950.h3
IbmPower System S924 \(9009-42g\) Firmware>= fw950.00, < fw950.h3
IbmPower System H924 \(9223-42s\) Firmware>= fw950.00, < fw950.h3
IbmPower System E950 \(9040-Mr9\) Firmware>= fw950.00, < fw950.h3
IbmPower System E980 \(9080-M9s\) Firmware>= fw950.00, < fw950.h3

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2026-17097?
IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the PowerVM hypervisor call interface. An attacker with root access to a guest partition can issue a specially crafted hypervisor call causing a virtual processor to become permanently unresponsive, requiring a full platform re-IPL to restore normal operation. In some cases this may also cause the guest to inject a small amount of data into hypervisor or partition memory with no attacker control over the target location. Successful exploitation results in an integrity and availability impact to the managed system.
How severe is CVE-2026-17097?
CVE-2026-17097 has a CVSS score of 6.7/10 (MEDIUM severity). The EPSS model estimates a 0.11% probability of exploitation in the next 30 days.
How do I fix CVE-2026-17097?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-17097?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST