CVE-2026-19739

MEDIUMCVSS 6.5/10EPSS 0.10%

Last modified

CVE-2026-19739 is a medium-severity vulnerability rated 6.5/10 on the CVSS scale. The Bluetooth Link Layer control procedure code in subsys/bluetooth/controller/ll_sw/ull_llcp_conn_upd.c retains the received RX node while a Connection Update / Connection Parameter procedure waits for its instant, so the node can later carry the host notification (llcp_rx_node_retain(), which marks it NODE_RX_TYPE_RETAIN and thereby suppresses the normal recycling in ull.c). The default: arm of llcp_rp_cu_rx() and llcp_lp_cu_rx() — the "invalid PDU, terminate the connection" path — completed the procedure without releasing that retained node. EPSS estimates a 0.10% chance of exploitation in the next 30 days.

Description

The Bluetooth Link Layer control procedure code in subsys/bluetooth/controller/ll_sw/ull_llcp_conn_upd.c retains the received RX node while a Connection Update / Connection Parameter procedure waits for its instant, so the node can later carry the host notification (llcp_rx_node_retain(), which marks it NODE_RX_TYPE_RETAIN and thereby suppresses the normal recycling in ull.c). The default: arm of llcp_rp_cu_rx() and llcp_lp_cu_rx() — the "invalid PDU, terminate the connection" path — completed the procedure without releasing that retained node. llcp_rr_check_done() then dequeued and freed the procedure context with ctx->node_ref.rx still pointing at the retained node, dropping the last reference to it. A peer device in radio range can reach this without pairing, bonding, or encryption. Against a peripheral, the peer sends a well-formed LL_CONNECTION_UPDATE_IND with an instant a few connection events in the future (the node is retained and the procedure enters RP_CU_STATE_WAIT_INSTANT), then, before the instant is reached, sends any other LL Control PDU such as LL_LENGTH_REQ. ull_cp_rx() routes that PDU into the active remote Connection Update procedure, which takes the invalid-PDU path. The central role is reachable symmetrically after accepting an LL_CONNECTION_PARAM_REQ, and the local-procedure variant is reachable with LL_REJECT_IND. With CONFIG_BT_CTLR_ASSERT_DEBUG enabled (its default), the resulting state violates the invariant asserted in llcp_rr_check_done(), so the two-PDU sequence produces an immediate fatal error in the controller. With those asserts disabled, each occurrence permanently loses one node from the controller's small fixed RX pool (sized from CONFIG_BT_CTLR_RX_BUFFERS, which defaults to 1); repeating the sequence across reconnections exhausts the pool, after which the link-layer receive path operates on a NULL node. The impact is an unauthenticated, remotely triggerable denial of service persisting until reboot; there is no memory-disclosure or memory-corruption consequence, since the leaked node simply becomes unreachable.

Metrics

EPSS Probability
0.10%

0.9th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
zephyrprojectzephyr>= 3.4.0, < 4.5.0

References

Timeline

Published
Last Modified
Status
Awaiting Analysis

Frequently Asked Questions

What is CVE-2026-19739?
The Bluetooth Link Layer control procedure code in subsys/bluetooth/controller/ll_sw/ull_llcp_conn_upd.c retains the received RX node while a Connection Update / Connection Parameter procedure waits for its instant, so the node can later carry the host notification (llcp_rx_node_retain(), which marks it NODE_RX_TYPE_RETAIN and thereby suppresses the normal recycling in ull.c). The default: arm of llcp_rp_cu_rx() and llcp_lp_cu_rx() — the "invalid PDU, terminate the connection" path — completed the procedure without releasing that retained node. llcp_rr_check_done() then dequeued and freed the procedure context with ctx->node_ref.rx still pointing at the retained node, dropping the last reference to it. A peer device in radio range can reach this without pairing, bonding, or encryption. Against a peripheral, the peer sends a well-formed LL_CONNECTION_UPDATE_IND with an instant a few connection events in the future (the node is retained and the procedure enters RP_CU_STATE_WAIT_INSTANT), then, before the instant is reached, sends any other LL Control PDU such as LL_LENGTH_REQ. ull_cp_rx() routes that PDU into the active remote Connection Update procedure, which takes the invalid-PDU path. The central role is reachable symmetrically after accepting an LL_CONNECTION_PARAM_REQ, and the local-procedure variant is reachable with LL_REJECT_IND. With CONFIG_BT_CTLR_ASSERT_DEBUG enabled (its default), the resulting state violates the invariant asserted in llcp_rr_check_done(), so the two-PDU sequence produces an immediate fatal error in the controller. With those asserts disabled, each occurrence permanently loses one node from the controller's small fixed RX pool (sized from CONFIG_BT_CTLR_RX_BUFFERS, which defaults to 1); repeating the sequence across reconnections exhausts the pool, after which the link-layer receive path operates on a NULL node. The impact is an unauthenticated, remotely triggerable denial of service persisting until reboot; there is no memory-disclosure or memory-corruption consequence, since the leaked node simply becomes unreachable.
How severe is CVE-2026-19739?
CVE-2026-19739 has a CVSS score of 6.5/10 (MEDIUM severity). The EPSS model estimates a 0.10% probability of exploitation in the next 30 days.
How do I fix CVE-2026-19739?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-19739?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST