CVE-2026-26985

MEDIUMCVSS 6.5/10EPSS 0.33%

Last modified

CVE-2026-26985 is a medium-severity vulnerability rated 6.5/10 on the CVSS scale. LORIS (Longitudinal Online Research and Imaging System) is a self-hosted web application that provides data- and project-management for neuroimaging research. Starting in version 24.0.0 and prior to versions 26.0.5, 27.0.2, and 28.0.0, an authenticated user with the appropriate authorization can read configuration files on the server by exploiting a path traversal vulnerability. EPSS estimates a 0.33% chance of exploitation in the next 30 days.

Description

LORIS (Longitudinal Online Research and Imaging System) is a self-hosted web application that provides data- and project-management for neuroimaging research. Starting in version 24.0.0 and prior to versions 26.0.5, 27.0.2, and 28.0.0, an authenticated user with the appropriate authorization can read configuration files on the server by exploiting a path traversal vulnerability. Some of these files contain hard-coded credentials. The vulnerability allows an attacker to read configuration files containing hard-coded credentials. The attacker could then authenticate to the database or other services if those credentials are reused. The attacker must be authenticated and have the required permissions. However, the vulnerability is easy to exploit and the application source code is public. This problem is fixed in LORIS v26.0.5 and v27.0.2 and above, and v28.0.0 and above. As a workaround, the electrophysiogy_browser in LORIS can be disabled by an administrator using the module manager.

Metrics

CVSS 3.1
6.5/10

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

EPSS Probability
0.33%

25.2th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
McgillLoris>= 24.0.0, < 26.0.5
McgillLoris>= 27.0.0, < 27.0.2

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2026-26985?
LORIS (Longitudinal Online Research and Imaging System) is a self-hosted web application that provides data- and project-management for neuroimaging research. Starting in version 24.0.0 and prior to versions 26.0.5, 27.0.2, and 28.0.0, an authenticated user with the appropriate authorization can read configuration files on the server by exploiting a path traversal vulnerability. Some of these files contain hard-coded credentials. The vulnerability allows an attacker to read configuration files containing hard-coded credentials. The attacker could then authenticate to the database or other services if those credentials are reused. The attacker must be authenticated and have the required permissions. However, the vulnerability is easy to exploit and the application source code is public. This problem is fixed in LORIS v26.0.5 and v27.0.2 and above, and v28.0.0 and above. As a workaround, the electrophysiogy_browser in LORIS can be disabled by an administrator using the module manager.
How severe is CVE-2026-26985?
CVE-2026-26985 has a CVSS score of 6.5/10 (MEDIUM severity). The EPSS model estimates a 0.33% probability of exploitation in the next 30 days.
How do I fix CVE-2026-26985?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2026-26985?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST