CVE-2026-30956 is a critical-severity vulnerability rated 9.9/10 on the CVSS scale. OneUptime is a solution for monitoring and managing online services. Prior to 10.0.21, a low‑privileged user can bypass authorization and tenant isolation in OneUptime v10.0.20 and earlier by sending a forged is-multi-tenant-query header together with a controlled projectid header. EPSS estimates a 0.49% chance of exploitation in the next 30 days.

Description

OneUptime is a solution for monitoring and managing online services. Prior to 10.0.21, a low‑privileged user can bypass authorization and tenant isolation in OneUptime v10.0.20 and earlier by sending a forged is-multi-tenant-query header together with a controlled projectid header. Because the server trusts this client-supplied header, internal permission checks in BasePermission are skipped and tenant scoping is disabled. This allows attackers to access project data belonging to other tenants, read sensitive User fields via nested relations, leak plaintext resetPasswordToken, and reset the victim’s password and fully take over the account. This results in cross‑tenant data exposure and full account takeover. This vulnerability is fixed in 10.0.21.

Metrics

CVSS 3.1
9.9/10

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H

EPSS Probability
0.49%

38.7th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
HackerbayOneuptime< 10.0.21

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2026-30956?
OneUptime is a solution for monitoring and managing online services. Prior to 10.0.21, a low‑privileged user can bypass authorization and tenant isolation in OneUptime v10.0.20 and earlier by sending a forged is-multi-tenant-query header together with a controlled projectid header. Because the server trusts this client-supplied header, internal permission checks in BasePermission are skipped and tenant scoping is disabled. This allows attackers to access project data belonging to other tenants, read sensitive User fields via nested relations, leak plaintext resetPasswordToken, and reset the victim’s password and fully take over the account. This results in cross‑tenant data exposure and full account takeover. This vulnerability is fixed in 10.0.21.
How severe is CVE-2026-30956?
CVE-2026-30956 has a CVSS score of 9.9/10 (CRITICAL severity). The EPSS model estimates a 0.49% probability of exploitation in the next 30 days.
How do I fix CVE-2026-30956?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.