CVE-2026-31971

HIGHCVSS 7.1/10EPSS 0.34%

Last modified

CVE-2026-31971 is a high-severity vulnerability rated 7.1/10 on the CVSS scale. HTSlib is a library for reading and writing bioinformatics file formats. CRAM is a compressed format which stores DNA sequence alignment data using a variety of encodings and compression methods. EPSS estimates a 0.34% chance of exploitation in the next 30 days.

Description

HTSlib is a library for reading and writing bioinformatics file formats. CRAM is a compressed format which stores DNA sequence alignment data using a variety of encodings and compression methods. When reading data encoded using the `BYTE_ARRAY_LEN` method, the `cram_byte_array_len_decode()` failed to validate that the amount of data being unpacked matched the size of the output buffer where it was to be stored. Depending on the data series being read, this could result either in a heap or a stack overflow with attacker-controlled bytes. Depending on the data stream this could result either in a heap buffer overflow or a stack overflow. If a user opens a file crafted to exploit this issue it could lead to the program crashing, overwriting of data structures on the heap or stack in ways not expected by the program, or changing the control flow of the program. It may be possible to use this to obtain arbitrary code execution. Versions 1.23.1, 1.22.2 and 1.21.1 include fixes for this issue. There is no workaround for this issue.

Metrics

CVSS 3.1
8.1/10

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H

CVSS 4.0
7.1/10

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

EPSS Probability
0.34%

25.4th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
HtslibHtslib< 1.21.1
HtslibHtslib>= 1.22, < 1.22.2
HtslibHtslib1.23

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2026-31971?
HTSlib is a library for reading and writing bioinformatics file formats. CRAM is a compressed format which stores DNA sequence alignment data using a variety of encodings and compression methods. When reading data encoded using the `BYTE_ARRAY_LEN` method, the `cram_byte_array_len_decode()` failed to validate that the amount of data being unpacked matched the size of the output buffer where it was to be stored. Depending on the data series being read, this could result either in a heap or a stack overflow with attacker-controlled bytes. Depending on the data stream this could result either in a heap buffer overflow or a stack overflow. If a user opens a file crafted to exploit this issue it could lead to the program crashing, overwriting of data structures on the heap or stack in ways not expected by the program, or changing the control flow of the program. It may be possible to use this to obtain arbitrary code execution. Versions 1.23.1, 1.22.2 and 1.21.1 include fixes for this issue. There is no workaround for this issue.
How severe is CVE-2026-31971?
CVE-2026-31971 has a CVSS score of 7.1/10 (HIGH severity). The EPSS model estimates a 0.34% probability of exploitation in the next 30 days.
How do I fix CVE-2026-31971?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2026-31971?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST