CVE-2026-34126

HIGHCVSS 7.3/10EPSS 0.10%

Last modified

CVE-2026-34126 is a high-severity vulnerability rated 7.3/10 on the CVSS scale. TP-Link has identified a vulnerability in Tapo L535E v1.0 and v3.0, Tapo P300 v1.0, and Tapo D100C v1.0, where Bluetooth communication during the initial setup phase is transmitted in cleartext without encryption. Bluetooth is only used during initialization. An attacker within the Bluetooth range could exploit this behavior using Bluetooth sniffing or man-in-the-middle techniques, which may allow eavesdropping on Bluetooth communication, manipulate transmitted setup data and potentially gain unauthorized control of the device during initialization.  An attacker within the Bluetooth range could exploit this behavior using Bluetooth sniffing or man-in-the-middle techniques, which may allow eavesdropping on Bluetooth communication, manipulate transmitted setup data and potentially gain unauthorized control of the device during initialization. D100C is the chime delivered with your Tapo camera, and it is delivered with the following Tapo products: D130, D210, D235, D225, TD21, TDB21 and TD25. EPSS estimates a 0.10% chance of exploitation in the next 30 days.

Description

TP-Link has identified a vulnerability in Tapo L535E v1.0 and v3.0, Tapo P300 v1.0, and Tapo D100C v1.0, where Bluetooth communication during the initial setup phase is transmitted in cleartext without encryption. Bluetooth is only used during initialization. An attacker within the Bluetooth range could exploit this behavior using Bluetooth sniffing or man-in-the-middle techniques, which may allow eavesdropping on Bluetooth communication, manipulate transmitted setup data and potentially gain unauthorized control of the device during initialization.  An attacker within the Bluetooth range could exploit this behavior using Bluetooth sniffing or man-in-the-middle techniques, which may allow eavesdropping on Bluetooth communication, manipulate transmitted setup data and potentially gain unauthorized control of the device during initialization. D100C is the chime delivered with your Tapo camera, and it is delivered with the following Tapo products: D130, D210, D235, D225, TD21, TDB21 and TD25

Metrics

CVSS 3.1
7.5/10

CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS 4.0
7.3/10

CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

EPSS Probability
0.10%

0.9th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
Tp-LinkTapo L535e Firmware1.4.1
Tp-LinkTapo P300 Firmware1.4.0
Tp-LinkTapo P300 Firmware1.4.2
Tp-LinkTapo D100c Firmware1.3.1

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2026-34126?
TP-Link has identified a vulnerability in Tapo L535E v1.0 and v3.0, Tapo P300 v1.0, and Tapo D100C v1.0, where Bluetooth communication during the initial setup phase is transmitted in cleartext without encryption. Bluetooth is only used during initialization. An attacker within the Bluetooth range could exploit this behavior using Bluetooth sniffing or man-in-the-middle techniques, which may allow eavesdropping on Bluetooth communication, manipulate transmitted setup data and potentially gain unauthorized control of the device during initialization.  An attacker within the Bluetooth range could exploit this behavior using Bluetooth sniffing or man-in-the-middle techniques, which may allow eavesdropping on Bluetooth communication, manipulate transmitted setup data and potentially gain unauthorized control of the device during initialization. D100C is the chime delivered with your Tapo camera, and it is delivered with the following Tapo products: D130, D210, D235, D225, TD21, TDB21 and TD25
How severe is CVE-2026-34126?
CVE-2026-34126 has a CVSS score of 7.3/10 (HIGH severity). The EPSS model estimates a 0.10% probability of exploitation in the next 30 days.
How do I fix CVE-2026-34126?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2026-34126?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST