CVE-2026-4638

HIGHCVSS 7.1/10

Last modified

CVE-2026-4638 is a high-severity vulnerability rated 7.1/10 on the CVSS scale. PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext.

Description

PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter.  Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.

Metrics

Weakness Enumeration

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
Paessler GmbHPRTG Network Monitor< 26.2.120.1449

References

Timeline

Published
Last Modified
Status
Deferred

Frequently Asked Questions

What is CVE-2026-4638?
PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter.  Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.
How severe is CVE-2026-4638?
CVE-2026-4638 has a CVSS score of 7.1/10 (HIGH severity).
How do I fix CVE-2026-4638?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps