CVE-2026-5496

UnknownEPSS 0.24%

Last modified

CVE-2026-5496 is a vulnerability of currently unknown severity. Labcenter Electronics Proteus PDSPRJ File Parsing Type Confusion Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Labcenter Electronics Proteus. EPSS estimates a 0.24% chance of exploitation in the next 30 days.

Description

Labcenter Electronics Proteus PDSPRJ File Parsing Type Confusion Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Labcenter Electronics Proteus. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDSPRJ files. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-25717.

Metrics

EPSS Probability
0.24%

15.3th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersionsUpdate
LabcenterProteus8.17Sp5

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2026-5496?
Labcenter Electronics Proteus PDSPRJ File Parsing Type Confusion Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Labcenter Electronics Proteus. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of PDSPRJ files. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-25717.
How severe is CVE-2026-5496?
Severity scoring for CVE-2026-5496 is pending analysis. The EPSS model estimates a 0.24% probability of exploitation in the next 30 days.
How do I fix CVE-2026-5496?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2026-5496?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST