CVE-2026-62424

MEDIUMCVSS 5.5/10

Last modified

CVE-2026-62424 is a medium-severity vulnerability rated 5.5/10 on the CVSS scale. [This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] The directory and Rock Ridge / SUSP walk in libfsimage's iso9660 driver derives several lengths directly from attacker-controlled on-disk fields without validating them: * The directory loop itself assumes a good record length. This is CVE-2026-42494. * The calculation of the System Use area may underflow.

Description

[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] The directory and Rock Ridge / SUSP walk in libfsimage's iso9660 driver derives several lengths directly from attacker-controlled on-disk fields without validating them: * The directory loop itself assumes a good record length. This is CVE-2026-42494. * The calculation of the System Use area may underflow. This is CVE-2026-42495. * The Rock Ridge extension loop assumes a good (inner) record length. This is CVE-2026-62423. * The Rock Ridge NM record processing assumes a good entry length. This is CVE-2026-62424. * The Rock Ridge CE record processing assumes a good size and offset. This is CVE-2026-62425.

Metrics

CVSS 3.1
5.5/10

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H

Weakness Enumeration

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
XenXenconsult Xen advisory XSA-497

References

Timeline

Published
Last Modified
Status
Deferred

Frequently Asked Questions

What is CVE-2026-62424?
[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] The directory and Rock Ridge / SUSP walk in libfsimage's iso9660 driver derives several lengths directly from attacker-controlled on-disk fields without validating them: * The directory loop itself assumes a good record length. This is CVE-2026-42494. * The calculation of the System Use area may underflow. This is CVE-2026-42495. * The Rock Ridge extension loop assumes a good (inner) record length. This is CVE-2026-62423. * The Rock Ridge NM record processing assumes a good entry length. This is CVE-2026-62424. * The Rock Ridge CE record processing assumes a good size and offset. This is CVE-2026-62425.
How severe is CVE-2026-62424?
CVE-2026-62424 has a CVSS score of 5.5/10 (MEDIUM severity).
How do I fix CVE-2026-62424?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-62424?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST