CVE-2026-75969

CRITICALCVSS 9.1/10

Last modified

CVE-2026-75969 is a critical-severity vulnerability rated 9.1/10 on the CVSS scale. Missing authentication for critical function vulnerability for all PTZOptics cameras and the Firmware Upgrade Tool - Firmware Update modules. A missing authentication vulnerability in the firmware update mechanism of affected PTZOptics cameras allows an unauthenticated user to install modified firmware on the device without administrator credentials. This vulnerability allows attackers to upload modified firmware to the device without admin credentials.

Description

Missing authentication for critical function vulnerability for all PTZOptics cameras and the Firmware Upgrade Tool - Firmware Update modules. A missing authentication vulnerability in the firmware update mechanism of affected PTZOptics cameras allows an unauthenticated user to install modified firmware on the device without administrator credentials. This vulnerability allows attackers to upload modified firmware to the device without admin credentials. This issue affects: * Move 4K 12X before: 0.0.98 * Move 4K 20X before: 0.1.33 * Move 4K 30X before: 2.1.17 * Link 4K 12X before: 0.0.99 * Link 4K 20X before: 0.1.37 * Link 4K 30X before: 2.1.18 * Move SE 12X before: 9.1.66 * Move SE 20X before: 9.1.44 * Move SE 30X before: 9.1.46 * Studio 4K 12X before: 8.3.32 * Studio 4K 20X before: 8.3.32 * Studio SE 12X before: 8.3.32 * Studio SE 20X before: 8.3.32 * All Generation 2 cameras, including: PT12X-SDI-GY-G2, PT12X-SDI-WH-G2, PT12X-NDI-GY-G2, PT12X-NDI-WH-G2; PT12X-USB-GY-G2, PT12X-USB-WH-G2; PT20X-SDI-GY-G2, PT20X-SDI-WH-G2, PT20X-NDI-GY-G2, PT20X-NDI-WH-G2; PT20X-USB-GY-G2, PT20X-USB-WH-G2; PT30X-SDI-GY-G2, PT30X-SDI-WH-G2, PT30X-NDI-GY-G2, PT30X-NDI-WH-G2; PTVL-ZCAM, PTVL-NDI-ZCAM; PTEPTZ-ZCAM-G2, PTEPTZ-NDI-ZCAM-G2; PT12X-ZCAM, PT12X-NDI-ZCAM; PT20X-ZCAM, PT20X-NDI-ZCAM; Studio Pro - All versions * Upgrade Tool - All versions

Metrics

Weakness Enumeration

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
PTZOpticsMove 4K 12X< 0.0.98
PTZOpticsMove 4K 20X< 0.1.33
PTZOpticsMove 4K 30X< 2.1.17
PTZOpticsLink 4K 12X< 0.0.99
PTZOpticsLink 4K 20X< 0.1.37
PTZOpticsLink 4K 30X< 2.1.18
PTZOpticsMove SE 12X< 9.1.66
PTZOpticsMove SE 20X< 9.1.44
PTZOpticsMove SE 30X< 9.1.46
PTZOpticsStudio 4K 12X< 8.3.32
PTZOpticsStudio 4K 20X< 8.3.32
PTZOpticsStudio SE 12X< 8.3.32
PTZOpticsStudio SE 20X< 8.3.32
PTZOpticsPT12X-SDI-GY-G2, PT12X-SDI-WH-G2, PT12X-NDI-GY-G2, PT12X-NDI-WH-G2All versions
PTZOpticsPT12X-USB-GY-G2, PT12X-USB-WH-G2All versions
PTZOpticsPT20X-SDI-GY-G2, PT20X-SDI-WH-G2, PT20X-NDI-GY-G2, PT20X-NDI-WH-G2All versions
PTZOpticsPT20X-USB-GY-G2, PT20X-USB-WH-G2All versions
PTZOpticsPT30X-SDI-GY-G2, PT30X-SDI-WH-G2, PT30X-NDI-GY-G2, PT30X-NDI-WH-G2All versions
PTZOpticsPTVL-ZCAM, PTVL-NDI-ZCAMAll versions
PTZOpticsPTEPTZ-ZCAM-G2, PTEPTZ-NDI-ZCAM-G2All versions
PTZOpticsPT12X-ZCAM, PT12X-NDI-ZCAMAll versions
PTZOpticsPT20X-ZCAM, PT20X-NDI-ZCAMAll versions
PTZOpticsStudio ProAll versions
PTZOpticsUpgrade ToolAll versions

References

Timeline

Published
Last Modified
Status
Deferred

Frequently Asked Questions

What is CVE-2026-75969?
Missing authentication for critical function vulnerability for all PTZOptics cameras and the Firmware Upgrade Tool - Firmware Update modules. A missing authentication vulnerability in the firmware update mechanism of affected PTZOptics cameras allows an unauthenticated user to install modified firmware on the device without administrator credentials. This vulnerability allows attackers to upload modified firmware to the device without admin credentials. This issue affects: * Move 4K 12X before: 0.0.98 * Move 4K 20X before: 0.1.33 * Move 4K 30X before: 2.1.17 * Link 4K 12X before: 0.0.99 * Link 4K 20X before: 0.1.37 * Link 4K 30X before: 2.1.18 * Move SE 12X before: 9.1.66 * Move SE 20X before: 9.1.44 * Move SE 30X before: 9.1.46 * Studio 4K 12X before: 8.3.32 * Studio 4K 20X before: 8.3.32 * Studio SE 12X before: 8.3.32 * Studio SE 20X before: 8.3.32 * All Generation 2 cameras, including: PT12X-SDI-GY-G2, PT12X-SDI-WH-G2, PT12X-NDI-GY-G2, PT12X-NDI-WH-G2; PT12X-USB-GY-G2, PT12X-USB-WH-G2; PT20X-SDI-GY-G2, PT20X-SDI-WH-G2, PT20X-NDI-GY-G2, PT20X-NDI-WH-G2; PT20X-USB-GY-G2, PT20X-USB-WH-G2; PT30X-SDI-GY-G2, PT30X-SDI-WH-G2, PT30X-NDI-GY-G2, PT30X-NDI-WH-G2; PTVL-ZCAM, PTVL-NDI-ZCAM; PTEPTZ-ZCAM-G2, PTEPTZ-NDI-ZCAM-G2; PT12X-ZCAM, PT12X-NDI-ZCAM; PT20X-ZCAM, PT20X-NDI-ZCAM; Studio Pro - All versions * Upgrade Tool - All versions
How severe is CVE-2026-75969?
CVE-2026-75969 has a CVSS score of 9.1/10 (CRITICAL severity).
How do I fix CVE-2026-75969?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-75969?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST