CVE-2026-80711

Unknown

Last modified

CVE-2026-80711 is a vulnerability of currently unknown severity. In the Linux kernel, the following vulnerability has been resolved: power: supply: max17040: handle missing status supplier MAX17040 does not report charger state itself, so the driver forwards POWER_SUPPLY_PROP_STATUS to a supplier power supply. If no supplier is registered, power_supply_get_property_from_supplier() returns -ENODEV and leaves the output value untouched. max17040_get_property() currently ignores that error and returns success, so userspace can read an uninitialized status value from the battery power supply.

Description

In the Linux kernel, the following vulnerability has been resolved: power: supply: max17040: handle missing status supplier MAX17040 does not report charger state itself, so the driver forwards POWER_SUPPLY_PROP_STATUS to a supplier power supply. If no supplier is registered, power_supply_get_property_from_supplier() returns -ENODEV and leaves the output value untouched. max17040_get_property() currently ignores that error and returns success, so userspace can read an uninitialized status value from the battery power supply. This happens on systems that use the fuel gauge without a charger supplier relationship in firmware. Return POWER_SUPPLY_STATUS_UNKNOWN when no supplier provides STATUS, and propagate other supplier lookup errors.

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
LinuxLinux>= f4b782af61ae7bbf93008d5809b0e3a8ac2bb88e, < 91ac995a6f4ddf4f92b231b080544abf23a9b871; >= f4b782af61ae7bbf93008d5809b0e3a8ac2bb88e, < b039f13e095d28a64ca6b21d0ee5440d8b048f37; >= f4b782af61ae7bbf93008d5809b0e3a8ac2bb88e, < ee2ea0c452edc0930e7395b080dccd5a1cb965e1; >= f4b782af61ae7bbf93008d5809b0e3a8ac2bb88e, < 725668c6b6aa3971fe850659102c250d0d676e18
LinuxLinux6.7

References

Timeline

Published
Last Modified
Status
Received

Frequently Asked Questions

What is CVE-2026-80711?
In the Linux kernel, the following vulnerability has been resolved: power: supply: max17040: handle missing status supplier MAX17040 does not report charger state itself, so the driver forwards POWER_SUPPLY_PROP_STATUS to a supplier power supply. If no supplier is registered, power_supply_get_property_from_supplier() returns -ENODEV and leaves the output value untouched. max17040_get_property() currently ignores that error and returns success, so userspace can read an uninitialized status value from the battery power supply. This happens on systems that use the fuel gauge without a charger supplier relationship in firmware. Return POWER_SUPPLY_STATUS_UNKNOWN when no supplier provides STATUS, and propagate other supplier lookup errors.
How severe is CVE-2026-80711?
Severity scoring for CVE-2026-80711 is pending analysis.
How do I fix CVE-2026-80711?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.