CVE-2026-80754

HIGHCVSS 7.8/10EPSS 0.21%

Last modified

CVE-2026-80754 is a high-severity vulnerability rated 7.8/10 on the CVSS scale. In the Linux kernel, the following vulnerability has been resolved: Input: synaptics-rmi4 - fix F55 transmitter electrode count typo During F55 sensor detection, the transmitter (TX) electrode count was incorrectly assigned the value of the receiver (RX) electrode count due to copy-paste typos. This incorrect value was then propagated to the driver data and used by F54 to determine the diagnostics report size. On devices with more RX than TX electrodes, this inflated the perceived TX count, leading to incorrect report size calculations and potential out-of-bounds buffer accesses. Fix the typos by correctly assigning the TX electrode counts.. EPSS estimates a 0.21% chance of exploitation in the next 30 days.

Description

In the Linux kernel, the following vulnerability has been resolved: Input: synaptics-rmi4 - fix F55 transmitter electrode count typo During F55 sensor detection, the transmitter (TX) electrode count was incorrectly assigned the value of the receiver (RX) electrode count due to copy-paste typos. This incorrect value was then propagated to the driver data and used by F54 to determine the diagnostics report size. On devices with more RX than TX electrodes, this inflated the perceived TX count, leading to incorrect report size calculations and potential out-of-bounds buffer accesses. Fix the typos by correctly assigning the TX electrode counts.

Metrics

EPSS Probability
0.21%

11.2th percentile

Probability of exploitation in the next 30 days. Learn more

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
LinuxLinux>= 6adba43fd222ea362c36296d1a6897c2e28fdc8e, < 6484e00d6778fdf2209cd75940bc3902b276457f; >= 6adba43fd222ea362c36296d1a6897c2e28fdc8e, < db4e20265ebda729610ca5cf45ca9437462c3f36; >= 6adba43fd222ea362c36296d1a6897c2e28fdc8e, < a6d9646e77da7cab2dff7043a8e9f75e23b836bc; >= 6adba43fd222ea362c36296d1a6897c2e28fdc8e, < 0739c65e799d4a93fe573ed23255a71fcfcc5438; >= 6adba43fd222ea362c36296d1a6897c2e28fdc8e, < 9759502f5cd71805923457f183ae5b9533e20c7b; >= 6adba43fd222ea362c36296d1a6897c2e28fdc8e, < 9b184c8337c6e12df129399007735a7fbcbbcb7b; >= 6adba43fd222ea362c36296d1a6897c2e28fdc8e, < a81cafe3c3c2f8494063385a7b0ea7ff407bf19f; >= 6adba43fd222ea362c36296d1a6897c2e28fdc8e, < 6058f0fea10f3caf63a435677358d1b8e9325114
LinuxLinux4.10

References

Timeline

Published
Last Modified
Status
Received

Frequently Asked Questions

What is CVE-2026-80754?
In the Linux kernel, the following vulnerability has been resolved: Input: synaptics-rmi4 - fix F55 transmitter electrode count typo During F55 sensor detection, the transmitter (TX) electrode count was incorrectly assigned the value of the receiver (RX) electrode count due to copy-paste typos. This incorrect value was then propagated to the driver data and used by F54 to determine the diagnostics report size. On devices with more RX than TX electrodes, this inflated the perceived TX count, leading to incorrect report size calculations and potential out-of-bounds buffer accesses. Fix the typos by correctly assigning the TX electrode counts.
How severe is CVE-2026-80754?
CVE-2026-80754 has a CVSS score of 7.8/10 (HIGH severity). The EPSS model estimates a 0.21% probability of exploitation in the next 30 days.
How do I fix CVE-2026-80754?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-80754?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST