CVE-2026-90394

Unknown

Last modified

CVE-2026-90394 is a vulnerability of currently unknown severity. In the Linux kernel, the following vulnerability has been resolved: power: supply: sc2731_charger: cancel work on remove The USB notifier and initial charger detection can schedule info->work. The remove path unregisters the notifier, but does not cancel queued or running work before the devm-allocated driver data is released. Set the platform drvdata used by remove, then cancel the work after unregistering the notifier. This issue was found by a static analysis tool..

Description

In the Linux kernel, the following vulnerability has been resolved: power: supply: sc2731_charger: cancel work on remove The USB notifier and initial charger detection can schedule info->work. The remove path unregisters the notifier, but does not cancel queued or running work before the devm-allocated driver data is released. Set the platform drvdata used by remove, then cancel the work after unregistering the notifier. This issue was found by a static analysis tool.

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
LinuxLinux>= 8ac1091ed18b4a6cb0dc2cd5653f080736f89392, < bb74a5ab30963022981381ea6aee176fd0c7957c; >= 8ac1091ed18b4a6cb0dc2cd5653f080736f89392, < 232e9e946b496e4706e2f34ce4a617460d8ae713; >= 8ac1091ed18b4a6cb0dc2cd5653f080736f89392, < 05c188addc6d1af51e28496e95096f4df9a000e9; >= 8ac1091ed18b4a6cb0dc2cd5653f080736f89392, < 972d88069050d0272b776145b824198b8f899dce; >= 8ac1091ed18b4a6cb0dc2cd5653f080736f89392, < c6df6e0c099086bc553d44410015cc81795070e6; >= 8ac1091ed18b4a6cb0dc2cd5653f080736f89392, < d5266b4c5c77152e386a3a2d9d5244b3b6cbd57a; >= 8ac1091ed18b4a6cb0dc2cd5653f080736f89392, < aab9d81a415c6653b44b057695ebfbba34dc9556; >= 8ac1091ed18b4a6cb0dc2cd5653f080736f89392, < dfc859bb8d332c525872f1a44028137724fa1998
LinuxLinux5.0

References

Timeline

Published
Last Modified
Status
Received

Frequently Asked Questions

What is CVE-2026-90394?
In the Linux kernel, the following vulnerability has been resolved: power: supply: sc2731_charger: cancel work on remove The USB notifier and initial charger detection can schedule info->work. The remove path unregisters the notifier, but does not cancel queued or running work before the devm-allocated driver data is released. Set the platform drvdata used by remove, then cancel the work after unregistering the notifier. This issue was found by a static analysis tool.
How severe is CVE-2026-90394?
Severity scoring for CVE-2026-90394 is pending analysis.
How do I fix CVE-2026-90394?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-90394?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST