CVE-2026-90725
Last modified
CVE-2026-90725 is a medium-severity vulnerability rated 4.9/10 on the CVSS scale. Dell PowerProtect Data Domain, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain a Stack-based Buffer Overflow vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.. EPSS estimates a 0.26% chance of exploitation in the next 30 days.
Description
Dell PowerProtect Data Domain, Feature Release versions 7.7.1.0 through 8.8, LTS2024 release versions 7.13.1.0 through 7.13.1.80, LTS2025 release versions 8.3.1.0 through 8.3.1.40, LTS2026 release versions 8.6.1.0 through 8.6.1.20, contain a Stack-based Buffer Overflow vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Denial of service.
Metrics
Weakness Enumeration
Affected Software
Source: CNA advisory (CVE.org). NVD analysis pending.
| Vendor | Product | Versions |
|---|---|---|
| Dell | PowerProtect Data Domain | < 8.9.0.0 or later; < 7.13.1.90 or later; < 8.3.1.50 or later; < 8.6.1.30 or later |
References
Timeline
- Published
- Last Modified
- Status
- Undergoing Analysis
Frequently Asked Questions
What is CVE-2026-90725?
How severe is CVE-2026-90725?
How do I fix CVE-2026-90725?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2026
- CVE-2026-90719Dell PowerProtect Data Domain Management Center, Feature Rel…2.7
- CVE-2026-9072IBM WebSphere Application Server and IBM WebSphere Applicati…9.8
- CVE-2026-90720Dell PowerProtect Data Domain, Feature Release versions 7.7.…6.7
- CVE-2026-90721Dell PowerProtect Data Domain, Feature Release versions 7.7.…3.4
- CVE-2026-90723Dell PowerProtect Data Domain Management Center, Feature Rel…2.7
- CVE-2026-90724Dell PowerProtect Data Domain Management Center, Feature Rel…2.7
- CVE-2026-90726Dell PowerProtect Data Domain, Feature Release versions 7.7.…6
- CVE-2026-90727Dell PowerProtect Data Domain, Feature Release versions 7.7.…3.8
- CVE-2026-90728Dell PowerProtect Data Domain, Feature Release versions 7.7.…6.3
- CVE-2026-90729Dell PowerProtect Data Domain, Feature Release versions 7.7.…6.7
- CVE-2026-9073A flaw was found in foreman-mcp-server. This component utili…6.2
- CVE-2026-90730Dell PowerProtect Data Domain, Feature Release versions 7.7.…6.5
Are you affected by CVE-2026-90725?