CVE-2026-91007

HIGHCVSS 7.8/10

Last modified

CVE-2026-91007 is a high-severity vulnerability rated 7.8/10 on the CVSS scale. The user-mode syscall verifiers for the charger driver API in drivers/charger/charger_handlers.c did not inspect the prop argument before copying union charger_propval across the user/kernel boundary. Two members of that union are function pointers — status_notification (CHARGER_PROP_STATUS_NOTIFICATION) and online_notification (CHARGER_PROP_ONLINE_NOTIFICATION), declared in include/zephyr/drivers/charger.h — and z_vrfy_charger_set_prop() forwarded the caller-supplied union verbatim to the driver's set_property callback for any property.

Description

The user-mode syscall verifiers for the charger driver API in drivers/charger/charger_handlers.c did not inspect the prop argument before copying union charger_propval across the user/kernel boundary. Two members of that union are function pointers — status_notification (CHARGER_PROP_STATUS_NOTIFICATION) and online_notification (CHARGER_PROP_ONLINE_NOTIFICATION), declared in include/zephyr/drivers/charger.h — and z_vrfy_charger_set_prop() forwarded the caller-supplied union verbatim to the driver's set_property callback for any property. z_vrfy_charger_get_prop() had the mirror defect and copied the stored kernel callback address back out to user memory. With CONFIG_USERSPACE enabled, any user-mode thread that has been granted a charger device object could call charger_set_prop() with CHARGER_PROP_STATUS_NOTIFICATION or CHARGER_PROP_ONLINE_NOTIFICATION and an arbitrary pointer value. Drivers that implement these properties — drivers/charger/charger_max20335.c, drivers/charger/charger_pf1550.c and drivers/charger/charger_bq2518x.c — store the pointer in device data and later invoke it from their interrupt work handlers, which run in supervisor mode, on any charger state change such as a cable plug/unplug. The result is a control-flow hijack at kernel privilege from an unprivileged thread, defeating the isolation that CONFIG_USERSPACE is meant to provide; the read path additionally disclosed a kernel code address to user mode, and clearing a notifier installed by a supervisor thread let user mode suppress charger notifications. Supervisor-mode callers of charger_set_prop()/charger_get_prop() are unaffected. The fix makes both verifiers reject the two notifier properties outright — including when the supplied callback is NULL, since the notifiers are device state — and adds a BUILD_ASSERT on CHARGER_PROP_COMMON_COUNT so that new properties force a re-review of the union's user-mode safety.

Metrics

Weakness Enumeration

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
zephyrprojectzephyr>= 3.7.0, < 4.3.2; >= 4.4.0, < 4.5.0

References

Timeline

Published
Last Modified
Status
Awaiting Analysis

Frequently Asked Questions

What is CVE-2026-91007?
The user-mode syscall verifiers for the charger driver API in drivers/charger/charger_handlers.c did not inspect the prop argument before copying union charger_propval across the user/kernel boundary. Two members of that union are function pointers — status_notification (CHARGER_PROP_STATUS_NOTIFICATION) and online_notification (CHARGER_PROP_ONLINE_NOTIFICATION), declared in include/zephyr/drivers/charger.h — and z_vrfy_charger_set_prop() forwarded the caller-supplied union verbatim to the driver's set_property callback for any property. z_vrfy_charger_get_prop() had the mirror defect and copied the stored kernel callback address back out to user memory. With CONFIG_USERSPACE enabled, any user-mode thread that has been granted a charger device object could call charger_set_prop() with CHARGER_PROP_STATUS_NOTIFICATION or CHARGER_PROP_ONLINE_NOTIFICATION and an arbitrary pointer value. Drivers that implement these properties — drivers/charger/charger_max20335.c, drivers/charger/charger_pf1550.c and drivers/charger/charger_bq2518x.c — store the pointer in device data and later invoke it from their interrupt work handlers, which run in supervisor mode, on any charger state change such as a cable plug/unplug. The result is a control-flow hijack at kernel privilege from an unprivileged thread, defeating the isolation that CONFIG_USERSPACE is meant to provide; the read path additionally disclosed a kernel code address to user mode, and clearing a notifier installed by a supervisor thread let user mode suppress charger notifications. Supervisor-mode callers of charger_set_prop()/charger_get_prop() are unaffected. The fix makes both verifiers reject the two notifier properties outright — including when the supplied callback is NULL, since the notifiers are device state — and adds a BUILD_ASSERT on CHARGER_PROP_COMMON_COUNT so that new properties force a re-review of the union's user-mode safety.
How severe is CVE-2026-91007?
CVE-2026-91007 has a CVSS score of 7.8/10 (HIGH severity).
How do I fix CVE-2026-91007?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-91007?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST