CVE-2026-93185

Unknown

Last modified

CVE-2026-93185 is a vulnerability of currently unknown severity. In the Linux kernel, the following vulnerability has been resolved: ASoC: rt700-sdw: always drain jack work on remove rt700_sdw_remove() drains jack_detect_work and jack_btn_check_work only when rt700->hw_init is true. That state bit is cleared by rt700_update_status() when the SoundWire slave becomes UNATTACHED, but a jack work item can already have been queued by rt700_interrupt_callback() or rt700_jack_init() while the device was initialized. Do not use hw_init as the remove-time guard for draining these work objects.

Description

In the Linux kernel, the following vulnerability has been resolved: ASoC: rt700-sdw: always drain jack work on remove rt700_sdw_remove() drains jack_detect_work and jack_btn_check_work only when rt700->hw_init is true. That state bit is cleared by rt700_update_status() when the SoundWire slave becomes UNATTACHED, but a jack work item can already have been queued by rt700_interrupt_callback() or rt700_jack_init() while the device was initialized. Do not use hw_init as the remove-time guard for draining these work objects. The delayed works are initialized during rt700_init(), so remove can cancel them unconditionally and pair the object lifetime with the codec-private data lifetime instead of a mutable hardware state bit. This issue was found by our static analysis tool and then confirmed by manual review of the SoundWire status, interrupt and remove paths. The remove path should drain work based on whether the work object exists, not on a runtime hardware state bit that can change after the work was queued. A QEMU PoC queued jack_detect_work, simulated SDW_SLAVE_UNATTACHED, and then entered remove. DEBUG_OBJECTS reported an active timer/work object associated with the rt700 jack work path after remove skipped the cancel. This is sent as an RFC because the practical trigger depends on SoundWire core remove ordering after an UNATTACHED status update. If remove cannot run after hw_init has been cleared while jack work is still pending, this is a defensive lifecycle cleanup rather than a reachable race on current systems.

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
LinuxLinux>= 737ee8bdf682cedb3c42b713d20ffa5c899591fb, < f1e21b7b977f5ae2955ecf3ab144da2578a4fe00; >= 737ee8bdf682cedb3c42b713d20ffa5c899591fb, < b81c2131dbb6fe04e27841bc719977c106177c61; >= 737ee8bdf682cedb3c42b713d20ffa5c899591fb, < 1bb23c9d68312e77cec81bdfb2cc385e2d2960f7; >= 737ee8bdf682cedb3c42b713d20ffa5c899591fb, < 45fcf435ffcc5f61a43bd9b19094dc52de6cbc05; >= 737ee8bdf682cedb3c42b713d20ffa5c899591fb, < 1e8fddab6cbe536dd02e61205e4b9bf97df6479b; >= 737ee8bdf682cedb3c42b713d20ffa5c899591fb, < a47f087877bb2bc57c3ccb714fc49abf45d28e12; >= 737ee8bdf682cedb3c42b713d20ffa5c899591fb, < 612ccf42acd14bb2685fa60c3495ca13e63e8989
LinuxLinux5.12

References

Timeline

Published
Last Modified
Status
Received

Frequently Asked Questions

What is CVE-2026-93185?
In the Linux kernel, the following vulnerability has been resolved: ASoC: rt700-sdw: always drain jack work on remove rt700_sdw_remove() drains jack_detect_work and jack_btn_check_work only when rt700->hw_init is true. That state bit is cleared by rt700_update_status() when the SoundWire slave becomes UNATTACHED, but a jack work item can already have been queued by rt700_interrupt_callback() or rt700_jack_init() while the device was initialized. Do not use hw_init as the remove-time guard for draining these work objects. The delayed works are initialized during rt700_init(), so remove can cancel them unconditionally and pair the object lifetime with the codec-private data lifetime instead of a mutable hardware state bit. This issue was found by our static analysis tool and then confirmed by manual review of the SoundWire status, interrupt and remove paths. The remove path should drain work based on whether the work object exists, not on a runtime hardware state bit that can change after the work was queued. A QEMU PoC queued jack_detect_work, simulated SDW_SLAVE_UNATTACHED, and then entered remove. DEBUG_OBJECTS reported an active timer/work object associated with the rt700 jack work path after remove skipped the cancel. This is sent as an RFC because the practical trigger depends on SoundWire core remove ordering after an UNATTACHED status update. If remove cannot run after hw_init has been cleared while jack work is still pending, this is a defensive lifecycle cleanup rather than a reachable race on current systems.
How severe is CVE-2026-93185?
Severity scoring for CVE-2026-93185 is pending analysis.
How do I fix CVE-2026-93185?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-93185?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST