CVE-2026-98676

Unknown

Last modified

CVE-2026-98676 is a vulnerability of currently unknown severity. In the Linux kernel, the following vulnerability has been resolved: iio: adc: ade9000: fix NULL pointer dereference in clkout registration ade9000_setup_clkout() passes NULL as the register address when registering a divider clock. During clock registration, the common clock framework calls clk_divider_recalc_rate(), which dereferences the address through readl().

Description

In the Linux kernel, the following vulnerability has been resolved: iio: adc: ade9000: fix NULL pointer dereference in clkout registration ade9000_setup_clkout() passes NULL as the register address when registering a divider clock. During clock registration, the common clock framework calls clk_divider_recalc_rate(), which dereferences the address through readl(). As a result, probing an ADE9000 configured as a clock provider with an external input clock crashes. CLKOUT passes CLKIN through without changing its rate. Register it as a 1:1 fixed-factor clock, which does not require register access. This change does not affect the configuration using the internal clock, for which the driver does not register a clock provider.

Affected Software

Source: CNA advisory (CVE.org). NVD analysis pending.

VendorProductVersions
LinuxLinux>= 81de7b4619fc3682a3bedaa7e8d6b2d67ab4e10a, < d2400175228fbc10b29c49a7b5f70a7e80d144dd; >= 81de7b4619fc3682a3bedaa7e8d6b2d67ab4e10a, < 134aa31a8d4e71f6ab1d155ad7b4502508832f72; >= 81de7b4619fc3682a3bedaa7e8d6b2d67ab4e10a, < 49ee1c6a3ebda6b7de06b2961b0e09c1c3fe536a
LinuxLinux6.18

References

Timeline

Published
Last Modified
Status
Received

Frequently Asked Questions

What is CVE-2026-98676?
In the Linux kernel, the following vulnerability has been resolved: iio: adc: ade9000: fix NULL pointer dereference in clkout registration ade9000_setup_clkout() passes NULL as the register address when registering a divider clock. During clock registration, the common clock framework calls clk_divider_recalc_rate(), which dereferences the address through readl(). As a result, probing an ADE9000 configured as a clock provider with an external input clock crashes. CLKOUT passes CLKIN through without changing its rate. Register it as a 1:1 fixed-factor clock, which does not require register access. This change does not affect the configuration using the internal clock, for which the driver does not register a clock provider.
How severe is CVE-2026-98676?
Severity scoring for CVE-2026-98676 is pending analysis.
How do I fix CVE-2026-98676?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

How Strix Helps

Related CVEs from 2026

Are you affected by CVE-2026-98676?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now