CVE-2018-1063
Last modified
CVE-2018-1063 is a vulnerability of currently unknown severity. Context relabeling of filesystems is vulnerable to symbolic link attack, allowing a local, unprivileged malicious entity to change the SELinux context of an arbitrary file to a context with few restrictions. This only happens when the relabeling process is done, usually when taking SELinux state from disabled to enable (permissive or enforcing). EPSS estimates a 0.39% chance of exploitation in the next 30 days.
Description
Context relabeling of filesystems is vulnerable to symbolic link attack, allowing a local, unprivileged malicious entity to change the SELinux context of an arbitrary file to a context with few restrictions. This only happens when the relabeling process is done, usually when taking SELinux state from disabled to enable (permissive or enforcing). The issue was found in policycoreutils 2.5-11.
Metrics
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Redhat | Enterprise Linux | 7.0 |
| Selinux Project | Selinux | All versions |
References
- https://bugzilla.redhat.com/show_bug.cgi?id=1550122Issue Tracking, Mitigation, Vendor Advisory
- https://bugzilla.redhat.com/show_bug.cgi?id=1550122Issue Tracking, Mitigation, Vendor Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2018-1063?
How severe is CVE-2018-1063?
How do I fix CVE-2018-1063?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2018
- CVE-2018-10622Medtronic MyCareLink Patient Monitor uses per-product creden…5.2
- CVE-2018-10623Delta Electronics Delta Industrial Automation DOPSoft versio…
- CVE-2018-10624In Johnson Controls Metasys System Versions 8.0 and prior an…
- CVE-2018-10626Medtronic MyCareLink Patient Monitor’s update service does n…4.4
- CVE-2018-10627Echelon SmartServer 1 all versions, SmartServer 2 all versio…9.8
- CVE-2018-10628AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2…
- CVE-2018-10630For Crestron TSW-X60 version prior to 2.001.0037.001 and MC3…
- CVE-2018-10631The 8840 Clinician Programmer executes the application progr…6.3
- CVE-2018-10632In Moxa NPort 5210, 5230, and 5232 versions 2.9 build 170307…
- CVE-2018-10633Universal Robots Robot Controllers Version CB 3.1, SW Versio…
- CVE-2018-10634Communications between Medtronic MiniMed MMT pumps and wirel…4.8
- CVE-2018-10635In Universal Robots Robot Controllers Version CB 3.1, SW Ver…
Are you affected by CVE-2018-1063?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST