CVE-2018-10634 is a medium-severity vulnerability rated 4.8/10 on the CVSS scale. Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.. EPSS estimates a 0.47% chance of exploitation in the next 30 days.
Description
Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these transmissions and extract sensitive information, such as device serial numbers.
Metrics
CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Medtronic | Minimed Paradigm Revel Mmt-523k Firmware | All versions |
| Medtronic | Minimed Paradigm Revel Mmt-723k Firmware | All versions |
| Medtronic | Minimed Paradigm Revel Mmt-723 Firmware | All versions |
| Medtronic | Minimed 530g Mmt-551 Firmware | All versions |
| Medtronic | Minimed Paradigm Real-Time Mmt-522 Firmware | All versions |
| Medtronic | Minimed Paradigm Real-Time Mmt-722 Firmware | All versions |
| Medtronic | Minimed 530g Mmt-751 Firmware | All versions |
| Medtronic | Minimed Paradigm Revel Mmt-523 Firmware | All versions |
| Medtronic | Minimed Paradigm 508 Insulin Pump Firmware | All versions |
References
- http://www.securityfocus.com/bid/105044Third Party Advisory, VDB Entry
- https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-02Third Party Advisory, US Government Resource
- http://www.securityfocus.com/bid/105044Third Party Advisory, VDB Entry
- https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-02Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2018-10634?
How severe is CVE-2018-10634?
How do I fix CVE-2018-10634?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2018
- CVE-2018-10628AVEVA InTouch 2014 R2 SP1 and prior, InTouch 2017, InTouch 2…
- CVE-2018-1063Context relabeling of filesystems is vulnerable to symbolic …
- CVE-2018-10630For Crestron TSW-X60 version prior to 2.001.0037.001 and MC3…
- CVE-2018-10631The 8840 Clinician Programmer executes the application progr…6.3
- CVE-2018-10632In Moxa NPort 5210, 5230, and 5232 versions 2.9 build 170307…
- CVE-2018-10633Universal Robots Robot Controllers Version CB 3.1, SW Versio…
- CVE-2018-10635In Universal Robots Robot Controllers Version CB 3.1, SW Ver…
- CVE-2018-10636CNCSoft Version 1.00.83 and prior with ScreenEditor Version …8.8
- CVE-2018-10637A maliciously crafted project file may cause a buffer overfl…
- CVE-2018-1064libvirt version before 4.2.0-rc1 is vulnerable to a resource…
- CVE-2018-10641D-Link DIR-601 A1 1.02NA devices do not require the old pass…
- CVE-2018-10642Command injection vulnerability in Combodo iTop 2.4.1 allows…
Are you affected by CVE-2018-10634?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST