CVE-2018-13811
Last modified
CVE-2018-13811 is a vulnerability of currently unknown severity. A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. EPSS estimates a 0.24% chance of exploitation in the next 30 days.
Description
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. The vulnerability could be exploited by an attacker with local access to the project file. No user interaction is required to exploit the vulnerability. The vulnerability could allow the attacker to obtain certain passwords from the project. At the time of advisory publication no public exploitation of this vulnerability was known.
Metrics
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Simatic Step 7 \(Tia Portal\) | < 15.1 |
References
- http://www.securityfocus.com/bid/105926Third Party Advisory, VDB Entry
- http://www.securityfocus.com/bid/105926Third Party Advisory, VDB Entry
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2018-13811?
How severe is CVE-2018-13811?
How do I fix CVE-2018-13811?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2018
- CVE-2018-13805A vulnerability has been identified in SIMATIC ET 200SP Open…
- CVE-2018-13806A vulnerability has been identified in SIEMENS TD Keypad Des…
- CVE-2018-13807A vulnerability has been identified in SCALANCE X300 (All ve…
- CVE-2018-13808A vulnerability has been identified in CP 1604 (All versions…
- CVE-2018-13809A vulnerability has been identified in CP 1604 (All versions…
- CVE-2018-13810A vulnerability has been identified in CP 1604 (All versions…
- CVE-2018-13812A vulnerability has been identified in SIMATIC HMI Comfort P…
- CVE-2018-13813A vulnerability has been identified in SIMATIC HMI Comfort P…
- CVE-2018-13814A vulnerability has been identified in SIMATIC HMI Comfort P…
- CVE-2018-13815A vulnerability has been identified in SIMATIC S7-1200 (All …
- CVE-2018-13816A vulnerability has been identified in TIM 1531 IRC (All ver…
- CVE-2018-13817Rejected reason: DO NOT USE THIS CANDIDATE NUMBER. ConsultID…
Are you affected by CVE-2018-13811?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST