CVE-2018-13812 is a vulnerability of currently unknown severity. A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. EPSS estimates a 3.57% chance of exploitation in the next 30 days.

Description

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Metrics

EPSS Probability
3.57%

87.9th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
SiemensSimatic Hmi Comfort Panels Firmware<= 15.0
SiemensSimatic Hmi Comfort Outdoor Panels Firmware<= 15.0
SiemensSimatic Hmi Ktp Mobile Panels Ktp400f Firmware<= 15.0
SiemensSimatic Hmi Ktp Mobile Panels Ktp700 Firmware<= 15.0
SiemensSimatic Hmi Ktp Mobile Panels Ktp700f Firmware<= 15.0
SiemensSimatic Hmi Ktp Mobile Panels Ktp900 Firmware<= 15.0
SiemensSimatic Hmi Ktp Mobile Panels Ktp900f Firmware<= 15.0
SiemensSimatic Wincc \(Tia Portal\)<= 15.0
SiemensSimatic Wincc Runtime<= 15.0
SiemensSimatic Hmi Tp FirmwareAll versions
SiemensSimatic Hmi Mp FirmwareAll versions
SiemensSimatic Hmi Op FirmwareAll versions

References

Timeline

Published
Last Modified
Status
Modified

Frequently Asked Questions

What is CVE-2018-13812?
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
How severe is CVE-2018-13812?
Severity scoring for CVE-2018-13812 is pending analysis. The EPSS model estimates a 3.57% probability of exploitation in the next 30 days.
How do I fix CVE-2018-13812?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2018-13812?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST