CVE-2019-18255
MEDIUMCVSS 5.5/10EPSS 0.20%
Last modified
CVE-2019-18255 is a medium-severity vulnerability rated 5.5/10 on the CVSS scale. HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through section objects. This may allow privilege escalation.. EPSS estimates a 0.20% chance of exploitation in the next 30 days.
Description
HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through section objects. This may allow privilege escalation.
Metrics
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Ge | Ifix | <= 6.1 |
References
- https://us-cert.cisa.gov/ics/advisories/icsa-21-040-01Third Party Advisory, US Government Resource
- https://us-cert.cisa.gov/ics/advisories/icsa-21-040-01Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2019-18255?
HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through section objects. This may allow privilege escalation.
How severe is CVE-2019-18255?
CVE-2019-18255 has a CVSS score of 5.5/10 (MEDIUM severity). The EPSS model estimates a 0.20% probability of exploitation in the next 30 days.
How do I fix CVE-2019-18255?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2019
- CVE-2019-1825A vulnerability in the web-based management interface of Cis…8.1
- CVE-2019-18250In all versions of ABB Power Generation Information Manager …9.8
- CVE-2019-18251In Omron CX-Supervisor, Versions 3.5 (12) and prior, Omron C…8.8
- CVE-2019-18252BIOTRONIK CardioMessenger II, The affected products allow cr…4.3
- CVE-2019-18253An attacker could use specially crafted paths in a specific …10
- CVE-2019-18254BIOTRONIK CardioMessenger II, The affected products do not e…4.6
- CVE-2019-18256BIOTRONIK CardioMessenger II, The affected products use indi…4.6
- CVE-2019-18257In Advantech DiagAnywhere Server, Versions 3.07.11 and prior…9.8
- CVE-2019-18259In Omron PLC CJ series, all versions and Omron PLC CS series…9.8
- CVE-2019-1826A vulnerability in the quality of service (QoS) feature of C…6.8
- CVE-2019-18261In Omron PLC CS series, all versions, Omron PLC CJ series, a…9.8
- CVE-2019-18263An issue was found in Philips Veradius Unity, Pulsera, and E…6.5
Are you affected by CVE-2019-18255?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST