CVE-2019-6542
Last modified
CVE-2019-6542 is a high-severity vulnerability rated 7.5/10 on the CVSS scale. ENTTEC Datagate MK2, Storm 24, Pixelator all firmware versions prior to (70044,70050,70060)_update_05032019-482 allows an unauthenticated user to initiate a remote reboot, which may be used to cause a denial of service condition.. EPSS estimates a 1.52% chance of exploitation in the next 30 days.
Description
ENTTEC Datagate MK2, Storm 24, Pixelator all firmware versions prior to (70044,70050,70060)_update_05032019-482 allows an unauthenticated user to initiate a remote reboot, which may be used to cause a denial of service condition.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Enttec | Datagate Mk2 Firmware | < 70044_update_05032019-482 |
| Enttec | Storm 24 Firmware | < 70050_update_05032019-482 |
| Enttec | Pixelator Firmware | < 70060_update_05032019-482 |
References
- https://ics-cert.us-cert.gov/advisories/ICSA-19-085-03-0Third Party Advisory, US Government Resource
- https://ics-cert.us-cert.gov/advisories/ICSA-19-085-03-0Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2019-6542?
How severe is CVE-2019-6542?
How do I fix CVE-2019-6542?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2019
- CVE-2019-6536Opening a specially crafted LCDS LAquis SCADA before 4.3.1.7…
- CVE-2019-6537Multiple stack-based buffer overflow vulnerabilities in WECO…7.8
- CVE-2019-6538The Conexus telemetry protocol utilized within Medtronic MyC…6.5
- CVE-2019-6539Several heap-based buffer overflow vulnerabilities in WECON …7.8
- CVE-2019-6540The Conexus telemetry protocol utilized within Medtronic MyC…6.5
- CVE-2019-6541A memory corruption vulnerability has been identified in WEC…7.8
- CVE-2019-6543AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1…9.8
- CVE-2019-6544GE Communicator, all versions prior to 4.0.517, has a servic…5.6
- CVE-2019-6545AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1…7.5
- CVE-2019-6546GE Communicator, all versions prior to 4.0.517, allows an at…7.8
- CVE-2019-6547Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Ve…5.5
- CVE-2019-6548GE Communicator, all versions prior to 4.0.517, contains two…9.8
Are you affected by CVE-2019-6542?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST