CVE-2020-15486
Last modified
CVE-2020-15486 is a medium-severity vulnerability rated 6.5/10 on the CVSS scale. An issue was discovered on Dr Trust ECG Pen 2.00.08 devices. Because the Bluetooth LE support is implemented without a requirement for pairing or security, any attacker can access the GATT server of the device and can sniff the data being broadcasted while a measurement is being done. EPSS estimates a 0.51% chance of exploitation in the next 30 days.
Description
An issue was discovered on Dr Trust ECG Pen 2.00.08 devices. Because the Bluetooth LE support is implemented without a requirement for pairing or security, any attacker can access the GATT server of the device and can sniff the data being broadcasted while a measurement is being done. Also, saved data can also be extracted over a Bluetooth connection. In addition, an attacker can launch a man-in-the-middle attack against data integrity.
Metrics
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Drtrust | Electrocardiogram Pen Firmware | 2.00.08 |
References
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2020-15486?
How severe is CVE-2020-15486?
How do I fix CVE-2020-15486?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2020
- CVE-2020-15480An issue was discovered in PassMark BurnInTest through 9.1, …8.8
- CVE-2020-15481An issue was discovered in PassMark BurnInTest v9.1 Build 10…7.8
- CVE-2020-15482An issue was discovered on Nescomed Multipara Monitor M1000 …7.8
- CVE-2020-15483An issue was discovered on Nescomed Multipara Monitor M1000 …6.8
- CVE-2020-15484An issue was discovered on Nescomed Multipara Monitor M1000 …7.5
- CVE-2020-15485An issue was discovered on Nescomed Multipara Monitor M1000 …5.5
- CVE-2020-15487Re:Desk 2.3 contains a blind unauthenticated SQL injection v…9.8
- CVE-2020-15488Re:Desk 2.3 allows insecure file upload.7.5
- CVE-2020-15489An issue was discovered on Wavlink WL-WN530HG4 M30HG4.V5030.…9.8
- CVE-2020-1549An elevation of privilege vulnerability exists when the Wind…7.8
- CVE-2020-15490An issue was discovered on Wavlink WL-WN530HG4 M30HG4.V5030.…9.8
- CVE-2020-15492An issue was discovered in INNEO Startup TOOLS 2017 M021 12.…9.8
Are you affected by CVE-2020-15486?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST