CVE-2020-7587
Last modified
CVE-2020-7587 is a high-severity vulnerability rated 8.2/10 on the CVSS scale. A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. EPSS estimates a 2.48% chance of exploitation in the next 30 days.
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:L
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Opcenter Execution Discrete | < 3.2 |
| Siemens | Opcenter Execution Foundation | < 3.2 |
| Siemens | Opcenter Execution Process | < 3.2 |
| Siemens | Opcenter Intelligence | < 3.3 |
| Siemens | Opcenter Quality | < 11.3 |
| Siemens | Opcenter Rd\&L | 8.0 |
| Siemens | Simatic It Lms | < 2.6 |
| Siemens | Simatic It Production Suite | < 8.0 |
| Siemens | Simatic Notifier Server | All versions |
| Siemens | Simatic Pcs Neo | < 3.0 |
| Siemens | Simatic Pcs Neo | 3.0 |
| Siemens | Simatic Step 7 | >= 15, < 15.1 |
| Siemens | Simatic Step 7 | 15.1 |
| Siemens | Simatic Step 7 | 16 |
| Siemens | Simocode Es | < 15.1 |
| Siemens | Simocode Es | 15.1 |
| Siemens | Simocode Es | 16 |
| Siemens | Soft Starter Es | < 15.1 |
| Siemens | Soft Starter Es | 15.1 |
References
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2020-7587?
How severe is CVE-2020-7587?
How do I fix CVE-2020-7587?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2020
- CVE-2020-7580A vulnerability has been identified in SIMATIC Automation To…6.7
- CVE-2020-7581A vulnerability has been identified in Opcenter Execution Di…6.7
- CVE-2020-7583A vulnerability has been identified in Automation License Ma…7.8
- CVE-2020-7584A vulnerability has been identified in SIMATIC S7-200 SMART …7.5
- CVE-2020-7585A vulnerability has been identified in SIMATIC PCS 7 V8.2 an…7.8
- CVE-2020-7586A vulnerability has been identified in SIMATIC PCS 7 V8.2 an…7.8
- CVE-2020-7588A vulnerability has been identified in Opcenter Execution Di…5.3
- CVE-2020-7589A vulnerability has been identified in LOGO! 8 BM (incl. SIP…9.1
- CVE-2020-7590A vulnerability has been identified in DCA Vantage Analyzer …6.8
- CVE-2020-7591A vulnerability has been identified in SIPORT MP (All versio…8.8
- CVE-2020-7592A vulnerability has been identified in SIMATIC HMI Basic Pan…6.5
- CVE-2020-7593A vulnerability has been identified in LOGO! 8 BM (incl. SIP…9.8
Are you affected by CVE-2020-7587?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST