CVE-2021-37182
Last modified
CVE-2021-37182 is a high-severity vulnerability rated 7.5/10 on the CVSS scale. A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5), SCALANCE XM416-4C (All versions < V6.5), SCALANCE XM416-4C (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 1x230V (All versions < V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 24V (All versions < V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 2x230V (All versions < V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 1x230V (All versions < V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 24V (All versions < V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 2x230V (All versions < V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR528-6M (All versions < V6.5), SCALANCE XR528-6M (2HR2) (All versions < V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions < V6.5), SCALANCE XR528-6M (L3 int.) (All versions < V6.5), SCALANCE XR552-12M (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions < V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. EPSS estimates a 0.59% chance of exploitation in the next 30 days.
Description
A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5), SCALANCE XM416-4C (All versions < V6.5), SCALANCE XM416-4C (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 1x230V (All versions < V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 24V (All versions < V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 2x230V (All versions < V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 1x230V (All versions < V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 24V (All versions < V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 2x230V (All versions < V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR528-6M (All versions < V6.5), SCALANCE XR528-6M (2HR2) (All versions < V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions < V6.5), SCALANCE XR528-6M (L3 int.) (All versions < V6.5), SCALANCE XR552-12M (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions < V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Scalance Xm408-4c Firmware | < 6.5 |
| Siemens | Scalance Xm408-4c L3 Firmware | < 6.5 |
| Siemens | Scalance Xm408-8c Firmware | < 6.5 |
| Siemens | Scalance Xm408-8c L3 Firmware | < 6.5 |
| Siemens | Scalance Xm416-4c Firmware | < 6.5 |
| Siemens | Scalance Xm416-4c L3 Firmware | < 6.5 |
| Siemens | Scalance Xr524-8c Firmware | < 6.5 |
| Siemens | Scalance Xr524-8c L3 Firmware | < 6.5 |
| Siemens | Scalance Xr526-8c Firmware | < 6.5 |
| Siemens | Scalance Xr526-8c L3 Firmware | < 6.5 |
| Siemens | Scalance Xr528-6m Firmware | < 6.5 |
| Siemens | Scalance Xr528-6m 2hr2 Firmware | < 6.5 |
| Siemens | Scalance Xr528-6m 2hr2 L3 Firmware | < 6.5 |
| Siemens | Scalance Xr528-6m L3 Firmware | < 6.5 |
| Siemens | Scalance Xr552-12m Firmware | < 6.5 |
| Siemens | Scalance Xr552-12m 2hr2 Firmware | < 6.5 |
| Siemens | Scalance Xr552-12m 2hr2 L3 Firmware | < 6.5 |
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-145224.pdfPatch, Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-145224.pdfPatch, Vendor Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2021-37182?
How severe is CVE-2021-37182?
How do I fix CVE-2021-37182?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2021
- CVE-2021-37177A vulnerability has been identified in SINEMA Remote Connect…6.5
- CVE-2021-37178A vulnerability has been identified in Solid Edge SE2021 (Al…5.5
- CVE-2021-37179A vulnerability has been identified in Solid Edge SE2021 (Al…7.8
- CVE-2021-3718A denial of service vulnerability was reported in some Think…4.6
- CVE-2021-37180A vulnerability has been identified in Solid Edge SE2021 (Al…7.8
- CVE-2021-37181A vulnerability has been identified in Cerberus DMS V4.0 (Al…10
- CVE-2021-37183A vulnerability has been identified in SINEMA Remote Connect…6.5
- CVE-2021-37184A vulnerability has been identified in Industrial Edge Manag…9.8
- CVE-2021-37185A vulnerability has been identified in SIMATIC Drive Control…7.5
- CVE-2021-37186A vulnerability has been identified in LOGO! CMR2020 (All ve…5.4
- CVE-2021-37187An issue was discovered on Digi TransPort devices through 20…6.5
- CVE-2021-37188An issue was discovered on Digi TransPort devices through 20…8.8
Are you affected by CVE-2021-37182?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST