CVE-2024-48971
Last modified
CVE-2024-48971 is a critical-severity vulnerability rated 9.3/10 on the CVSS scale. The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician privileges.. EPSS estimates a 0.22% chance of exploitation in the next 30 days.
Description
The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician privileges.
Metrics
CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Weakness Enumeration
References
Timeline
- Published
- Last Modified
- Status
- Deferred
Frequently Asked Questions
What is CVE-2024-48971?
How severe is CVE-2024-48971?
How do I fix CVE-2024-48971?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2024
- CVE-2024-48963The package Snyk CLI before 1.1294.0 is vulnerable to Code I…9.8
- CVE-2024-48964The package Snyk CLI before 1.1294.0 is vulnerable to Code I…8.8
- CVE-2024-48966The software tools used by service personnel to test & calib…10
- CVE-2024-48967The ventilator and the Service PC lack sufficient audit logg…10
- CVE-2024-4897parisneo/lollms-webui, in its latest version, is vulnerable …8.4
- CVE-2024-48970The ventilator's microcontroller lacks memory protection. An…9.3
- CVE-2024-48973The debug port on the ventilator's serial interface is enabl…9.3
- CVE-2024-48974The ventilator does not perform proper file integrity checks…9.3
- CVE-2024-4898The InstaWP Connect – 1-click WP Staging & Migration plugin …9.8
- CVE-2024-48981An issue was discovered in MBed OS 6.16.0. During processing…7.5
- CVE-2024-48982An issue was discovered in MBed OS 6.16.0. Its hci parsing s…7.5
- CVE-2024-48983An issue was discovered in MBed OS 6.16.0. During processing…7.5
Are you affected by CVE-2024-48971?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST