CVE-2024-48974
Last modified
CVE-2024-48974 is a critical-severity vulnerability rated 9.3/10 on the CVSS scale. The ventilator does not perform proper file integrity checks when adopting firmware updates. This makes it possible for an attacker to force unauthorized changes to the device's configuration settings and/or compromise device functionality by pushing a compromised/illegitimate firmware file. EPSS estimates a 0.15% chance of exploitation in the next 30 days.
Description
The ventilator does not perform proper file integrity checks when adopting firmware updates. This makes it possible for an attacker to force unauthorized changes to the device's configuration settings and/or compromise device functionality by pushing a compromised/illegitimate firmware file. This could disrupt the function of the device and/or cause unauthorized information disclosure.
Metrics
CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Weakness Enumeration
References
Timeline
- Published
- Last Modified
- Status
- Deferred
Frequently Asked Questions
What is CVE-2024-48974?
How severe is CVE-2024-48974?
How do I fix CVE-2024-48974?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2024
- CVE-2024-48966The software tools used by service personnel to test & calib…10
- CVE-2024-48967The ventilator and the Service PC lack sufficient audit logg…10
- CVE-2024-4897parisneo/lollms-webui, in its latest version, is vulnerable …8.4
- CVE-2024-48970The ventilator's microcontroller lacks memory protection. An…9.3
- CVE-2024-48971The Clinician Password and Serial Number Clinician Password …9.3
- CVE-2024-48973The debug port on the ventilator's serial interface is enabl…9.3
- CVE-2024-4898The InstaWP Connect – 1-click WP Staging & Migration plugin …9.8
- CVE-2024-48981An issue was discovered in MBed OS 6.16.0. During processing…7.5
- CVE-2024-48982An issue was discovered in MBed OS 6.16.0. Its hci parsing s…7.5
- CVE-2024-48983An issue was discovered in MBed OS 6.16.0. During processing…7.5
- CVE-2024-48984An issue was discovered in MBed OS 6.16.0. When parsing hci …9.8
- CVE-2024-48985An issue was discovered in MBed OS 6.16.0. During processing…7.5
Are you affected by CVE-2024-48974?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST