CVE-2025-11781

HIGHCVSS 8.6/10EPSS 0.12%

Last modified

CVE-2025-11781 is a high-severity vulnerability rated 8.6/10 on the CVSS scale. Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. EPSS estimates a 0.12% chance of exploitation in the next 30 days.

Description

Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create valid firmware update packages. This bypasses all intended access controls and grants full administrative privileges.

Metrics

CVSS 3.1
7.8/10

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

CVSS 4.0
8.6/10

CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

EPSS Probability
0.12%

2.1th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
CircutorSge-Plc1000 Firmware9.0.2
CircutorSge-Plc50 Firmware9.0.2

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2025-11781?
Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create valid firmware update packages. This bypasses all intended access controls and grants full administrative privileges.
How severe is CVE-2025-11781?
CVE-2025-11781 has a CVSS score of 8.6/10 (HIGH severity). The EPSS model estimates a 0.12% probability of exploitation in the next 30 days.
How do I fix CVE-2025-11781?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2025-11781?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now