CVE-2025-11785

HIGHCVSS 8.5/10EPSS 0.33%

Last modified

CVE-2025-11785 is a high-severity vulnerability rated 8.5/10 on the CVSS scale. Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. EPSS estimates a 0.33% chance of exploitation in the next 30 days.

Description

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.

Metrics

CVSS 3.1
9.8/10

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

CVSS 4.0
8.5/10

CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

EPSS Probability
0.33%

24.6th percentile

Probability of exploitation in the next 30 days. Learn more

Weakness Enumeration

Affected Software

VendorProductVersions
CircutorSge-Plc1000 Firmware9.0.2
CircutorSge-Plc50 Firmware9.0.2

References

Timeline

Published
Last Modified
Status
Analyzed

Frequently Asked Questions

What is CVE-2025-11785?
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.
How severe is CVE-2025-11785?
CVE-2025-11785 has a CVSS score of 8.5/10 (HIGH severity). The EPSS model estimates a 0.33% probability of exploitation in the next 30 days.
How do I fix CVE-2025-11785?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.

Are you affected by CVE-2025-11785?

Run a free Strix scan to check your systems for this vulnerability.

Scan your code now

Source: NVD / NIST