CVE-2025-36751
Last modified
CVE-2025-36751 is a critical-severity vulnerability rated 9.4/10 on the CVSS scale. Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.. EPSS estimates a 0.06% chance of exploitation in the next 30 days.
Description
Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.
Metrics
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Weakness Enumeration
References
Timeline
- Published
- Last Modified
- Status
- Deferred
Frequently Asked Questions
What is CVE-2025-36751?
How severe is CVE-2025-36751?
How do I fix CVE-2025-36751?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2025
- CVE-2025-36745SolarEdge SE3680H ships with an outdated Linux kernel conta…7.8
- CVE-2025-36746SolarEdge monitoring platform contains a Cross‑Site Scriptin…5.4
- CVE-2025-36747ShineLan-X contains a set of credentials for an FTP server w…9.8
- CVE-2025-36748ShineLan-X contains a stored cross site scripting (XSS) vuln…5.4
- CVE-2025-3675A vulnerability was found in TOTOLINK A3700R 9.1.2u.5822_B20…5.3
- CVE-2025-36750ShineLan-X contains a stored cross site scripting (XSS) vuln…5.4
- CVE-2025-36752Growatt ShineLan-X communication dongle has an undocumented …9.8
- CVE-2025-36753The SWD debug interface on the Growatt ShineLan-X communicat…9.8
- CVE-2025-36754The authentication mechanism on web interface is not properl…9.3
- CVE-2025-36755The CleverDisplay BlueOne hardware player is designed with i…2.4
- CVE-2025-36756A problem with missing authorization on SolaX Cloud platform…5.8
- CVE-2025-36757It is possible to bypass the administrator login screen on S…6.3
Are you affected by CVE-2025-36751?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST