CVE-2025-36753
CRITICALCVSS 9.8/10EPSS 0.27%
Last modified
CVE-2025-36753 is a critical-severity vulnerability rated 9.8/10 on the CVSS scale. The SWD debug interface on the Growatt ShineLan-X communication dongle is available by default, allowing an attacker to attain debug access to the device and to extracting secrets or domains from within the device. EPSS estimates a 0.27% chance of exploitation in the next 30 days.
Description
The SWD debug interface on the Growatt ShineLan-X communication dongle is available by default, allowing an attacker to attain debug access to the device and to extracting secrets or domains from within the device
Metrics
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Growatt | Shine Lan-X Firmware | >= 3.6.0.0, < 3.6.0.2 |
References
- https://csirt.divd.nl/CVE-2025-36753/Third Party Advisory
Timeline
- Published
- Last Modified
- Status
- Analyzed
Frequently Asked Questions
What is CVE-2025-36753?
The SWD debug interface on the Growatt ShineLan-X communication dongle is available by default, allowing an attacker to attain debug access to the device and to extracting secrets or domains from within the device
How severe is CVE-2025-36753?
CVE-2025-36753 has a CVSS score of 9.8/10 (CRITICAL severity). The EPSS model estimates a 0.27% probability of exploitation in the next 30 days.
How do I fix CVE-2025-36753?
Check the vendor references and advisories linked above for patched versions and mitigation guidance. You can also run a Strix scan to test if your systems are affected.
How Strix Helps
- Same Subject, Wrong User: A Cross-Issuer Account Takeover in n8nStrix found an identity-binding bug in n8n's token-exchange flow enabling account takeover.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2025
- CVE-2025-36747ShineLan-X contains a set of credentials for an FTP server w…9.8
- CVE-2025-36748ShineLan-X contains a stored cross site scripting (XSS) vuln…5.4
- CVE-2025-3675A vulnerability was found in TOTOLINK A3700R 9.1.2u.5822_B20…5.3
- CVE-2025-36750ShineLan-X contains a stored cross site scripting (XSS) vuln…5.4
- CVE-2025-36751Encryption is missing on the configuration interface for Gro…9.4
- CVE-2025-36752Growatt ShineLan-X communication dongle has an undocumented …9.8
- CVE-2025-36754The authentication mechanism on web interface is not properl…9.3
- CVE-2025-36755The CleverDisplay BlueOne hardware player is designed with i…2.4
- CVE-2025-36756A problem with missing authorization on SolaX Cloud platform…5.8
- CVE-2025-36757It is possible to bypass the administrator login screen on S…6.3
- CVE-2025-36758It is possible to bypass the clipping level of authenticatio…6.3
- CVE-2025-36759Through the provision of user names, SolaX Cloud will sugges…8.7
Are you affected by CVE-2025-36753?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST