CVE-2017-1272
Last modified
CVE-2017-1272 is a low-severity vulnerability rated 3.7/10 on the CVSS scale. IBM Security Guardium 10.0 and 10.5 stores sensitive information in URL parameters. This may lead to information disclosure if unauthorized parties have access to the URLs via server logs, referrer header or browser history. EPSS estimates a 1.67% chance of exploitation in the next 30 days.
Description
IBM Security Guardium 10.0 and 10.5 stores sensitive information in URL parameters. This may lead to information disclosure if unauthorized parties have access to the URLs via server logs, referrer header or browser history. IBM X-Force ID: 124747. IBM X-Force ID: 124747.
Metrics
CVSS:3.0/A:N/AC:H/AV:N/C:L/I:N/PR:N/S:U/UI:N/E:U/RC:C/RL:O
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Ibm | Security Guardium | >= 10.0, <= 10.5 |
References
- http://www.securityfocus.com/bid/106237Third Party Advisory, VDB Entry
- https://exchange.xforce.ibmcloud.com/vulnerabilities/124747VDB Entry, Vendor Advisory
- https://www.ibm.com/support/docview.wss?uid=ibm10731655Vendor Advisory
- http://www.securityfocus.com/bid/106237Third Party Advisory, VDB Entry
- https://exchange.xforce.ibmcloud.com/vulnerabilities/124747VDB Entry, Vendor Advisory
- https://www.ibm.com/support/docview.wss?uid=ibm10731655Vendor Advisory
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2017-1272?
How severe is CVE-2017-1272?
How do I fix CVE-2017-1272?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2017
- CVE-2017-12713An Incorrect Permission Assignment for Critical Resource iss…
- CVE-2017-12714Abbott Laboratories pacemakers manufactured prior to Aug 28,…
- CVE-2017-12716Abbott Laboratories Accent and Anthem pacemakers manufacture…
- CVE-2017-12717An Uncontrolled Search Path Element issue was discovered in …
- CVE-2017-12718A Classic Buffer Overflow issue was discovered in Smiths Med…
- CVE-2017-12719An Untrusted Pointer Dereference issue was discovered in Adv…
- CVE-2017-12720An Improper Access Control issue was discovered in Smiths Me…
- CVE-2017-12721An Improper Certificate Validation issue was discovered in S…
- CVE-2017-12722An Out-of-bounds Read issue was discovered in Smiths Medical…
- CVE-2017-12723A Password in Configuration File issue was discovered in Smi…
- CVE-2017-12724A Use of Hard-coded Credentials issue was discovered in Smit…
- CVE-2017-12725A Use of Hard-coded Credentials issue was discovered in Smit…
Are you affected by CVE-2017-1272?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST