CVE-2017-12720
Last modified
CVE-2017-12720 is a vulnerability of currently unknown severity. An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections.. EPSS estimates a 1.89% chance of exploitation in the next 30 days.
Description
An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections.
Metrics
Weakness Enumeration
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Smiths-Medical | Medfusion 4000 Wireless Syringe Infusion Pump | 1.1 |
| Smiths-Medical | Medfusion 4000 Wireless Syringe Infusion Pump | 1.5 |
| Smiths-Medical | Medfusion 4000 Wireless Syringe Infusion Pump | 1.6 |
References
- http://www.securityfocus.com/bid/100665Third Party Advisory, VDB Entry
- https://ics-cert.us-cert.gov/advisories/ICSMA-17-250-02AThird Party Advisory, US Government Resource
- http://www.securityfocus.com/bid/100665Third Party Advisory, VDB Entry
- https://ics-cert.us-cert.gov/advisories/ICSMA-17-250-02AThird Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2017-12720?
How severe is CVE-2017-12720?
How do I fix CVE-2017-12720?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2017
- CVE-2017-12714Abbott Laboratories pacemakers manufactured prior to Aug 28,…
- CVE-2017-12716Abbott Laboratories Accent and Anthem pacemakers manufacture…
- CVE-2017-12717An Uncontrolled Search Path Element issue was discovered in …
- CVE-2017-12718A Classic Buffer Overflow issue was discovered in Smiths Med…
- CVE-2017-12719An Untrusted Pointer Dereference issue was discovered in Adv…
- CVE-2017-1272IBM Security Guardium 10.0 and 10.5 stores sensitive informa…3.7
- CVE-2017-12721An Improper Certificate Validation issue was discovered in S…
- CVE-2017-12722An Out-of-bounds Read issue was discovered in Smiths Medical…
- CVE-2017-12723A Password in Configuration File issue was discovered in Smi…
- CVE-2017-12724A Use of Hard-coded Credentials issue was discovered in Smit…
- CVE-2017-12725A Use of Hard-coded Credentials issue was discovered in Smit…
- CVE-2017-12726A Use of Hard-coded Password issue was discovered in Smiths …