CVE-2019-25720
Last modified
CVE-2019-25720 is a high-severity vulnerability rated 7.1/10 on the CVSS scale. Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.. EPSS estimates a 0.20% chance of exploitation in the next 30 days.
Description
Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.
Metrics
Weakness Enumeration
Affected Software
Source: CNA advisory (CVE.org). NVD analysis pending.
| Vendor | Product | Versions |
|---|---|---|
| Dräger | SC 6002XL | SC 6002XL |
| Dräger | SC6802XL | SC6802XL |
| Dräger | SC 7000 | SC 7000 |
| Dräger | SC8000 | SC8000 |
| Dräger | SC90000 XL | SC90000 XL |
References
Timeline
- Published
- Last Modified
- Status
- Awaiting Analysis
Frequently Asked Questions
What is CVE-2019-25720?
How severe is CVE-2019-25720?
How do I fix CVE-2019-25720?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2019
- CVE-2019-25715Rejected reason: This CVE ID has been rejected or withdrawn …
- CVE-2019-25716Dräger Infinity Delta, Delta XL, and Kappa patient monitors …7.5
- CVE-2019-25717Dräger Infinity Delta, Delta XL, and Kappa patient monitors …5.3
- CVE-2019-25718Dräger Infinity Explorer C700 contains a privilege escalatio…7.8
- CVE-2019-25719Dräger Infinity Acute Care System and Standalone Infinity M5…8.8
- CVE-2019-2572Vulnerability in the Oracle SOA Suite component of Oracle Fu…
- CVE-2019-25721Dräger Infinity M300 patient worn monitors with software ver…7.1
- CVE-2019-25722Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000,…7.6
- CVE-2019-25723Dräger Perseus A500 software versions 2.00 through 2.02 cont…6.3
- CVE-2019-25724Dräger Infinity M300 patient worn monitors with software ver…7.1
- CVE-2019-25725Rejected reason: This CVE ID has been rejected or withdrawn …
- CVE-2019-25726All in One Video Downloader 1.2 contains an SQL injection vu…8.8
Are you affected by CVE-2019-25720?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST