CVE-2015-3959
Last modified
CVE-2015-3959 is a vulnerability of currently unknown severity. The firmware in MNS before 4.5.6 on Belden GarrettCom Magnum 6K and Magnum 10K switches has a hardcoded serial-console password for a privileged account, which might allow physically proximate attackers to obtain access by establishing a console session to a nonstandard installation on which this account is enabled, and leveraging knowledge of this password.. EPSS estimates a 0.38% chance of exploitation in the next 30 days.
Description
The firmware in MNS before 4.5.6 on Belden GarrettCom Magnum 6K and Magnum 10K switches has a hardcoded serial-console password for a privileged account, which might allow physically proximate attackers to obtain access by establishing a console session to a nonstandard installation on which this account is enabled, and leveraging knowledge of this password.
Metrics
Affected Software
| Vendor | Product | Versions |
|---|---|---|
| Garrettcom | Magnum 10k Firmware | <= 4.5.5 |
| Garrettcom | Magnum 6k Firmware | <= 4.5.5 |
References
- https://ics-cert.us-cert.gov/advisories/ICSA-15-167-01Third Party Advisory, US Government Resource
- https://ics-cert.us-cert.gov/advisories/ICSA-15-167-01Third Party Advisory, US Government Resource
Timeline
- Published
- Last Modified
- Status
- Modified
Frequently Asked Questions
What is CVE-2015-3959?
How severe is CVE-2015-3959?
How do I fix CVE-2015-3959?
How Strix Helps
- How Strix found a critical auth bypass in etcdStrix autonomously discovered a critical authentication bypass in etcd, later designated CVE-2026-33413.
- Autonomous PentestingAI agents that find and validate exploitable vulnerabilities like this one across your applications.
- PR ReviewsPentest every pull request so vulnerable code is caught before it ships to production.
- AI Penetration TestingHow AI-driven penetration testing continuously covers your attack surface.
Related CVEs from 2015
- CVE-2015-3953Hard-coded accounts may be used to access Hospira Plum A+ In…
- CVE-2015-3954Hospira Plum A+ Infusion System version 13.4 and prior, Plum…
- CVE-2015-3955Stack-based buffer overflow in Hospira LifeCare PCA Infusion…
- CVE-2015-3956Hospira Plum A+ Infusion System version 13.4 and prior, Plum…
- CVE-2015-3957Hospira LifeCare PCA Infusion System before 7.0 stores priva…
- CVE-2015-3958Hospira LifeCare PCA Infusion System 5.0 and earlier, and po…
- CVE-2015-3960The firmware in MNS before 4.5.6 on Belden GarrettCom Magnum…
- CVE-2015-3961The web-server component in MNS before 4.5.6 on Belden Garre…
- CVE-2015-3962Schneider Electric StruxureWare Building Expert MPM before 2…
- CVE-2015-3963Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before …
- CVE-2015-3964SMA Solar Sunny WebBox has hardcoded passwords, which makes …
- CVE-2015-3965Hospira Symbiq Infusion System 3.13 and earlier allows remot…
Are you affected by CVE-2015-3959?
Run a free Strix scan to check your systems for this vulnerability.
Scan your code nowSource: NVD / NIST